EasyManua.ls Logo

Toshiba Carrier MCY-MAP0487HS-UL User Manual

Toshiba Carrier MCY-MAP0487HS-UL
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation Manual 1
English
Manuel d’installation 28
Français
Manual de instalación 57
Español
AIR CONDITIONER (MULTI TYPE)
Installation Manual
For OUTDOOR USE only
Pour une UTILISATION EN
EXTÉRIEUR uniquement
Solo para USO EXTERIOR
Outdoor Unit
Model name:
Heat Pump Model
MCY-MAP0367HS-UL
MCY-MAP0487HS-UL
MCY-MAP0607HS-UL
+00_EB99809701_00Ta.book Page 1 Tuesday, December 6, 2016 2:07 PM

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Toshiba Carrier MCY-MAP0487HS-UL and is the answer not in the manual?

Toshiba Carrier MCY-MAP0487HS-UL Specifications

General IconGeneral
ModelMCY-MAP0487HS-UL
CategoryHeat Pump
Cooling Capacity48000 BTU/h
Seasonal Coefficient of Performance (SCOP)4.0
Refrigerant TypeR410A
Heating Season Performance Factor (HSPF)9.0
Power Supply208-230V/60Hz/1Ph

Summary

Safety Precautions and Guidelines

R410A Air Conditioner Installation

Required Tools for R410A Installation

Lists necessary tools for R410A refrigerant system installation.

Handling Cautions for R410A

Safety precautions specific to handling R410A refrigerant.

Installation Conditions Overview

Refrigerant Piping Installation

Refrigerant Piping Connection

Pipe Connection Method: Flaring

Details the method for connecting refrigerant pipes using flaring.

Refrigerant Piping Component Selection

Piping Parts Selection Guide

Guide for selecting appropriate piping parts based on unit and capacity.

Refrigerant Piping Length and Height Limits

Airtight Test Procedure

Conducting the Airtight Test

Step-by-step instructions for conducting an airtight test.

Air Purge Process

Vacuum Purging Method

Instructions for purging air from the system using a vacuum pump.

Adding Refrigerant

Refrigerant Charge Calculation

Method for calculating and adding refrigerant based on pipe length.

Refrigerant Charging

Refrigerant Charging Steps

Steps for charging liquid refrigerant into the unit.

Electric Wiring Requirements

Address Setting Procedure

Setting Indoor and System Addresses

Steps for setting indoor unit addresses and system addresses.

Automatic Address Setting

Automatic Address Setting Procedure 1

Steps for automatic address setting for single refrigerant lines.

Automatic Address Setting Procedure 2

Steps for automatic address setting for multiple refrigerant lines.

System Address Switch Settings

Setting System Addresses via DIP Switches

Details switch settings on the interface P.C. board for system addresses.

Manual Address Setting with Remote Control

Changing Indoor Unit Address via Wired Remote

Changing Address for Single Refrigerant Line

Steps to change indoor unit addresses for a single refrigerant line.

Changing Address for Multiple Refrigerant Lines

Steps to change indoor unit addresses for multiple refrigerant lines.

Factory Default Address Reset

Resetting via Wired Remote Control

Resetting addresses using a direct wired remote control.

Resetting via Connector and DIP Switch

Resetting addresses via connector and DIP switch settings.

Test Run Procedures

Test Run via Outdoor Unit PC Board

Troubleshooting Guide

Refrigerant Leakage Warnings

Related product manuals