Category | Air Conditioner |
---|---|
Heating Capacity | 3.2 kW |
Indoor Unit Weight | 9 kg |
Refrigerant | R32 |
Power Source | 220-240V/50Hz |
Outdoor Unit Dimensions (HxWxD) | 550×780×285 mm |
Explains the meaning of danger, warning, and caution symbols used in the manual.
Explains the meaning of prohibited, mandatory, and caution marks used in the manual.
Instructs to confirm warning labels on the main unit and refer to the parts disassembly diagram.
Highlights safety precautions related to the new R410A refrigerant and its properties.
Lists precautions for installation and service work involving R410A refrigerant and tools.
Details the types and requirements for copper pipes and joints used with R410A refrigerant.
Lists essential tools required for working with R410A refrigerant and their interchangeability.
Provides detailed specifications for the 4-Way Cassette type indoor units.
Provides detailed specifications for the Compact 4-Way Cassette type indoor units.
Provides detailed specifications for the Ceiling type indoor units.
Provides detailed specifications for the High Wall type indoor units.
Shows external views and dimensions for the 4-Way Cassette type indoor units.
Shows external views and dimensions for Compact 4-Way Cassette type indoor units.
Shows external views and dimensions for Ceiling type indoor units.
Shows external views and dimensions for High Wall type indoor units.
Provides wiring diagrams for 4-Way Cassette type indoor units.
Provides wiring diagrams for Compact 4-Way Cassette type indoor units.
Provides wiring diagrams for Ceiling type indoor units.
Provides wiring diagrams for High Wall type indoor units.
Lists parts ratings for 4-Way Cassette type indoor units.
Lists parts ratings for Compact 4-Way Cassette type indoor units.
Lists parts ratings for Ceiling type indoor units.
Lists parts ratings for High Wall type indoor units.
Outlines control functions for 4-Way Cassette, Compact 4-Way, and Ceiling types.
Explains automatic capacity control based on temperature differences.
Details how air speed selection is controlled in cooling and heating modes.
Describes measures to prevent cold air discharge during heating operations.
Explains freeze prevention control logic based on sensor readings during cooling.
Details the indoor unit's control for cooling oil recovery from the outdoor unit.
Explains heating refrigerant oil recovery control for the indoor unit.
Describes compensation control for short intermittent operations.
Outlines the operation and control of the drain pump.
Explains the process of eliminating retained heat after heating operation stops.
Describes the display of the filter sign and its reset mechanism.
Explains the display indicators for operation readiness and pre-heat status.
Details the selection and setting of central control modes for TCC-LINK and wired remote controllers.
Explains louver position and swing setup for 4-way cassette and ceiling type units.
Describes the operation and detection of fan lock for DC motors.
Explains the start, performance, and retention of save operation.
Outlines control functions specific to High Wall type indoor units.
Explains the unit's behavior when power supply is reset.
Details how operation modes are selected via the remote controller.
Describes the adjustment range and correction of room temperature settings.
Explains automatic capacity control based on temperature differences.
Details how air speed selection is controlled via remote controller.
Describes measures to prevent cold air discharge during heating operations.
Explains freeze prevention control logic based on sensor readings during cooling.
Details the indoor unit's control for cooling oil recovery from the outdoor unit.
Explains heating refrigerant oil recovery control for the indoor unit.
Describes compensation control for short intermittent operations.
Explains the process of eliminating retained heat after heating operation stops.
Describes the display of the filter sign and its reset mechanism.
Explains the display indicators for operation readiness and pre-heat status.
Details the selection and setting of central control modes for TCC-LINK and wireless remote controllers.
Explains louver position and swing setup for 4-way cassette and ceiling type units.
Describes the Hi POWER operation for cooling and heating modes.
Details the COMFORT SLEEP operation for cooling and heating modes.
Explains how to memorize and operate preset settings using the remote controller.
Describes the QUIET operation mode for cooling, heating, and fan-only modes.
Explains the SLEEP operation mode and its timer settings.
Explains the start, performance, and retention of save operation.
Shows the block diagram of the indoor controller for various remote controller configurations.
Explains how to perform cooling and heating test runs using the remote controller.
Details specifications for optional switches and connectors on high wall type P.C. boards.
Provides an overview of troubleshooting, including applicable models, tools, and general checks.
Details the method for troubleshooting based on check codes displayed on controllers or interface boards.
Lists and explains check codes detected by the indoor unit.
Lists and explains check codes detected by the outdoor unit interface.
Explains how to troubleshoot based on information displayed on the remote controller.
Details how to interpret information displayed on the remote controller, including 7-segment symbols.
Explains how to use indoor unit indicator lights to identify faults on wireless type units.
Describes indications that do not involve check codes, such as test run status.
Lists check codes displayed on controllers and outdoor units, with locations to check.
Lists errors detected by the TCC-LINK central control device.
Shows temperature sensor characteristics for indoor units, including TA, TC1, TC2, TCJ sensors.
Details detachment and attachment procedures for parts of 4-Way Cassette type units.
Details detachment and attachment procedures for parts of Compact 4-Way Cassette type units.
Details detachment and attachment procedures for parts of Ceiling type units.
Details detachment and attachment procedures for parts of High Wall type units.
Outlines procedures for exchanging P.C. boards for 4-Way Cassette, Compact 4-Way, and Ceiling types.
Provides important notes and cautions for replacing the indoor P.C. board assembly.
Details the procedure for reading setting data from the EEPROM via the remote controller.
Explains how to replace the P.C. board and establish correspondence with the remote controller.
Details the procedure for writing setting data into the EEPROM of the service P.C. board.
Outlines P.C. board replacement procedures for High Wall type units.
Details the procedure for reading setup data from EEPROM for High Wall type units.
Explains how to replace the service P.C. board for High Wall type units.
Details the procedure for writing setup contents to EEPROM for High Wall type units.
Shows exploded views and parts lists for 4-Way Cassette type models.
Shows exploded views and parts lists for Compact 4-way Cassette type models.
Shows exploded views and parts lists for Ceiling type models.
Shows exploded views and parts lists for High Wall type models.
Explains the check of refrigerant concentration limits in rooms, including calculations and standards.