Details the meaning of safety indications like DANGER, WARNING, CAUTION.
Explains the meaning of safety marks such as Forbidden, Mandatory, Caution.
Instructions to confirm warning labels are indicated on specified positions on the unit.
Highlights safety considerations specific to R410A refrigerant, including pressure differences.
Provides critical cautions for installation and service work involving R410A refrigerant.
Specifies the required materials for refrigerant pipes and joints when using R410A.
Lists tools exclusive to R410A and those common with conventional refrigerants.
Details technical specifications for 4-Way Cassette indoor units.
Details technical specifications for Compact 4-Way Cassette indoor units.
Details technical specifications for Ceiling Type indoor units.
Details technical specifications for High Wall Type indoor units.
Provides external dimensional views and installation details for 4-Way Cassette units.
Provides external dimensional views and installation details for 4-Way Cassette units.
Provides external dimensional views and installation details for 4-Way Cassette units.
Provides external dimensional views and installation details for Compact 4-Way Cassette units.
Provides external dimensional views and installation details for Ceiling Type units.
Provides external dimensional views and installation details for High Wall Type units.
Illustrates the electrical wiring for 4-Way Cassette indoor units.
Illustrates the electrical wiring for Compact 4-Way Cassette indoor units.
Illustrates the electrical wiring for Ceiling Type indoor units.
Illustrates the electrical wiring for High Wall Type indoor units.
Lists the ratings for components used in 4-Way Cassette indoor units.
Lists the ratings for components used in Compact 4-Way Cassette indoor units.
Lists the ratings for components used in Ceiling Type indoor units.
Lists the ratings for components used in High Wall Type indoor units.
Details the control logic and operations for 4-Way, Compact, and Ceiling types.
Details the control logic and operations for High Wall Type units.
Shows the block diagram of the indoor unit's controller system.
Explains the connection procedure for a wireless remote controller kit.
Details the connection for systems using both wired and wireless remote controllers.
Illustrates the layout and components of the MCC-1570 PC board.
Illustrates the layout and components of the MCC-1402 PC board.
Lists optional connector functions and their specifications.
Lists optional connector specifications specific to High Wall Type units.
Details the steps for performing cooling and heating test runs.
Outlines the procedure for conducting a test run using a wireless remote controller.
Explains how to use the function to check indoor unit operation.
Provides instructions on how to clear errors from the system.
Details the application of remote location ON/OFF control box.
Lists control items and wiring diagrams for remote control interface.
Explains the function and operation of ventilating fan control via remote controller.
Provides wiring details for the remote controller based ventilating fan control.
Describes the function, control items, and operation of Leaving-ON prevention.
Details the power peak-cut function for indoor units.
Procedure to confirm indoor unit addresses using a wired remote controller.
Procedure to confirm the position of indoor units based on their addresses.
Explains how to clear errors using the remote controller.
Details methods for clearing errors for both outdoor and indoor units.
Describes how to call up and view monitoring data on the remote controller.
Outlines the steps to monitor system status via the remote controller.
Explains the meaning of LED indicators on the PC board.
Details the procedure for selecting wireless remote controller A or B.
Lists applicable models and the necessary tools for troubleshooting.
Outlines the systematic procedure for troubleshooting faults.
Lists and explains check codes detected by indoor units.
Lists and explains check codes detected by the main remote controller.
Lists and explains errors detected by the central control device.
Lists and explains check codes detected by outdoor units.
Details how to check and test faults using the remote controller display.
Explains how to access and interpret error history.
Provides guidance on how to read and interpret information displayed on the remote.
Provides resistance vs. temperature data for indoor unit sensors.
Instructions for detaching components of 4-Way Cassette indoor units.
Procedures for detaching components of Compact 4-Way Cassette indoor units.
Procedures for detaching components of Ceiling Type indoor units.
Procedures for detaching components of High Wall Type indoor units.
Procedures for exchanging PC boards in 4-Way, Compact, and Ceiling types.
Important notes and considerations before and after replacing an indoor PC board.
Step-by-step guide for replacing the service P.C. board.
Instructions for writing setting data into the EEPROM of the new P.C. board.
Overview of the PC board replacement process for High Wall type.
Method to read EEPROM data using a wired remote controller before replacement.
Method to write EEPROM data when original data cannot be read.
Steps to read setup data from the EEPROM using the remote controller.
Steps for replacing the service P.C. board and establishing correspondence.
Explains the method for setting DIP switches on the P.C. board.
Steps to write setup data into the EEPROM after board replacement.
Provides an exploded view and parts list for 4-Way Cassette indoor units.
Provides an exploded view and parts list for 4-Way Cassette indoor units.
Exploded view and parts list for the RBC-U31PG remote receiver.
Exploded view and parts list for the RBC-AX31U remote receiver.
Provides an exploded view and parts list for Compact 4-Way Cassette units.
Provides an exploded view and parts list for Ceiling Type indoor units.
Provides an exploded view and parts list for High Wall Type units.
Provides an exploded view and parts list for High Wall Type units.
Information on checking refrigerant concentration limits in rooms.
Details the standards for minimum room volume and concentration limits.