© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO163/166/203/206
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 57
2
1372 Counter Heater and energizing time
accumulating counter Dis-
play/0 clearing
ALL 0
<8 digits>
M Counts up the heater
control time accumu-
lated (when power of
the equipment is ON)
but does not count at
the Sleep Mode.
1
1378 Counter Counter for period of time
fuser unit is at ready tem-
perature
ALL 0
<8 digits>
M Counts up the heater
control time accumu-
lated (when the equip-
ment is at ready status).
1
1380 Counter Counter for period of time
fuser unit is at printing tem-
perature
ALL 0
<8 digits>
M Counts up the heater
control time accumu-
lated (during printing).
1
1382 Counter Counter for period of time
fuser unit is at energy sav-
ing temperature/Counter
reset
ALL 0
<8 digits>
M Counts up the heater
control time accumu-
lated (when the equip-
ment is in the Energy
Saving Mode).
1
1385 Counter Number of output pages
(Thick paper 1)
ALL 0
<8 digits>
M Counts up when the
registration sensor is
ON.
1
1386 Counter Number of output pages
(Thick paper 2)
ALL 0
<8 digits>
M Counts up when the
registration sensor is
ON.
1
1388 Counter Number of output pages
(OHP film)
ALL 0
<8 digits>
M Counts up when the
registration sensor is
ON.
1
1410 Counter Counter for period of toner
cartridge rotation time
ALL 0
<8 digits>
M Counts up the period of
rotation time of the
toner cartridge.
1
1411 Counter Counter for envelope ALL 0
<8 digits>
M Counts up when the
registration sensor is
ON.
1
1628-0 Process-
ing
Drum life correction switch-
ing of the drum reverse
rotation amount
ALL 4
<0-15>
M Drum life correction
switching of the drum
reverse rotation amount
1
1628-1 Process-
ing
Drum life correction switch-
ing of the normal drum
rotation amount after the
reverse rotation
ALL 9
<0-15>
M Drum life correction
switching of the normal
drum rotation amount
after the reverse rota-
tion
1
1913 Process-
ing
The function clear LED
blinks
PPC 1
<0-1>
SYS Blinks when the value is
different from the
present default value
after copying (until auto
clear or all clear.)
0: Invalid (Always off)
1: Valid
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM Contents
Proce-
dure
06/05