8 kw
1
1/14 kw
Air to Water Heat Pump
Engineering Data Book
Hydro Unit
HWS-803XWHM3-E
HWS-803XWHT6-E
HWS-803XWHD6-E
HWS-803XWHT9-E
HWS-1403XWHM3-E
HWS-1403XWHT6-E
HWS-1403XWHD6-E
HWS-1403XWHT9-E
Outdoor Unit
HWS-803H-E
HWS-1103H-E
HWS-1403H-E
HWS-1103H8-E
HWS-1403H8-E
HWS-1603H8-E
HWS-1103H8R-E
HWS-1403H8R-E
HWS-1603H8R-E
Hot Water Cylinder
HWS-1501CSHM3-E
HWS-2101CSHM3-E
HWS-3001CSHM3-E
HWS-1501CSHM3-UK
HWS-2101CSHM3-UK
HWS-3001CSHM3-UK
E10-371
2
Table of Contents
Table of Contents
2
Default Chapter
1
Outdoor Unit
1
1 Introduction
3
2 System Overview
7
System Combination
8
Hydro Unit
8
Outdoor Unit
9
Hot Water Cylinder
9
Options
10
3 System Specification
11
4 Hydro Unit
13
Specification
13
Dimension
17
Piping Diagram
19
Wiring Diagram
21
Capacity Tables
27
Q-H Characteristics of Hydro Unit
57
Options
58
5 Outdoor Unit
60
Specification
61
Dimension
64
Piping Diagram
66
Wiring Diagram
67
Sound Data
72
Operation Range
77
6 Hot Water Cylinder
79
Specification
80
Dimension
81
Piping Diagram
82
Wiring Diagram
84
7 Hydro Unit Installation Manual
85
Installation Manual
86
Air to Water Heat Pump Installation Manual
87
General Information
88
Accessory Parts
89
Preparations for Installation
90
General Safety Precautions
91
Precautions for Safety
91
Example of Hydro Unit Installation
93
Main Components of Hydro Unit
95
Hydro Unit Installation
97
Electrical Installation
103
Wiring Specifications
105
Start up and Configuration
115
Maintenance
124
Test Run
124
Sensor Temperature Monitoring Function
125
Troubleshooting
126
8 Outdoor Unit Installation Manual
133
Table of Contents
136
Default Chapter
139
Precautions for Safety
139
Accessory Parts and Refrigerant
141
Installation of New Refrigerant Air to Water Heat Pump
142
Installation Conditions
143
Before Installation
143
Installation Location
144
Installation of Outdoor Unit
146
Refrigerant Piping
147
Air Purging
150
Electrical Work
152
Air to Water Heat Pump Operating Conditions
155
Annual Maintenance
155
Earthing
155
Finishing
155
Test Run
155
Functions to be Implemented Locally
156
Troubleshooting
157
Appendix
159
9 Owner's Manual
163
Safety Precautions
166
Names and Functions of Parts
168
How to Use Functions
171
Timer Setting
171
Hot Water
172
User Maintenance
176
Air to Water Heat Pump Operations and Performance
176
General Specifications
177
Troubleshooting
178
Other manuals for Toshiba HWS-803XWHM3-E
Owner's Manual
58 pages
Service Manual
212 pages
Installation Manual
48 pages
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Toshiba HWS-803XWHM3-E and is the answer not in the manual?
Ask a question
Toshiba HWS-803XWHM3-E Specifications
General
Type
Heat Pump
Cooling Capacity (kW)
8.0
Heating Capacity (kW)
9.0
SEER
6.1
Power Supply
220-240V, 50Hz
Max. Current
15 A
Related product manuals
Toshiba HWS-803H-E
212 pages
Toshiba HWS-805H-E
29 pages
Toshiba HWS-802XWHM3-E
168 pages
Toshiba HWS-804XWHM3-E
58 pages
Toshiba HWS-804XWHM3 series
64 pages
Toshiba ESTIA HWS-802XWHM3-E
58 pages
Toshiba HWS-P805HR-E
184 pages
Toshiba HWS-1403XWHT6-E
58 pages
Toshiba HWS-G2601ENXR-E
74 pages
Toshiba HWS-G2601CNMR-E
74 pages
Toshiba HWS-P1105XWHT6-E
184 pages
Toshiba HWS-P804XWHM3-E1(TR)
172 pages