Hydro Unit
Installation Manual
– 1 –
Original instructions
Please read this Installation Manual carefully before installing the Air to Water Heat Pump.
This Manual describes the installation method of the Hydro Unit.
For installation of the Outdoor Unit, follow the Installation Manual attached to the Outdoor Unit.
This system is for residential use only.
REFRIGERANT
This Air to Water Heat Pump uses an HFC refrigerant (R32) in order to prevent destruction of the ozone layer.
1-EN
2-EN
Contents
1 General information ..................................................................................................... 1
2 Accessory parts ........................................................................................................... 2
3 Preparations for installation ........................................................................................ 3
4 Precautions for safety .................................................................................................. 3
5 Example of Hydro Unit installation ............................................................................. 6
6 Main components of Hydro Unit ................................................................................. 7
7 Hydro Unit installation ................................................................................................. 8
8 Group Control and optional controllers ................................................................... 20
9 Start up and configuration......................................................................................... 21
10 Maintenance ................................................................................................................ 33
11 Troubleshooting ......................................................................................................... 33
12 Technical parameters ................................................................................................. 37
1 General information
System combination
Outdoor Unit
Hydro Unit
HWT-
401HW-E
HWT-
601HW-E
HWT-
801HW-E
HWT-
1101HW-E
HWT-
1401HW-E
HWT-
801HRW-E
HWT-
1101HRW-E
HWT-
1401HRW-E
Backup
heater type
HWT-601XWHM3W-E
011-1W0467*
011-1W0467*
~,3kW
HWT-601XWHM6W-E
~,6kW
HWT-601XWHT6W-E
011-1W0467*
011-1W0467*
3N~,6kW
HWT-1101XWHM3W-E
011-1W0468*
011-1W0468*
011-1W0468*
011-1W0468*
~,3kW
HWT-1101XWHM6W-E
~,6kW
HWT-1101XWHT6W-E
011-1W0468*
011-1W0468*
011-1W0468*
011-1W0468*
3N~,6kW
HWT-1101XWHT9W-E
011-1W0468*
011-1W0468*
011-1W0468*
011-1W0468*
3N~,9kW
HWT-1401XWHM3W-E
~,3kW
HWT-1401XWHM6W-E
~,6kW
HWT-1401XWHT6W-E
3N~,6kW
HWT-1401XWHT9W-E
3N~,9kW
Single phase model Single phase with Cord Heater
*Keymark certification number
General specifications
Outdoor Unit
Single Phase model
Outdoor Unit HWT-401HW-E HWT-601HW-E HWT-801HW-E HWT-1101HW-E HWT-1401HW-E
Power supply 220-240 V ~50 Hz
Type INVERTER
Function Heating & Cooling
Heating
Capacity (kW) 4.0 6.0 8.0 11.0 14.0
Input (kW) 0.77 1.25 1.54 2.39 3.04
COP (W/W) 5.20 4.80 5.19 4.60 4.60
Cooling
Capacity (kW) 4.0 5.0 6.0 8.0 10.0
Input (kW) 1.16 1.52 1.88 2.86 4.08
COP (W/W) 3.45 3.30 3.20 2.80 2.45
Refrigerant R32
Dimension H x W x D (mm) 630 x 800 x 300 1,050 x 1,010 X 370
Outdoor Unit
with cord heater
HWT-801HRW-E HWT-1101HRW-E HWT-1401HRW-E
Power supply 220-240 V ~50 Hz
Type INVERTER
Function Heating & Cooling
Heating
Capacity (kW) 8.0 11.0 14.0
Input (kW) 1.54 2.39 3.04
COP (W/W) 5.19 4.60 4.60
Cooling
Capacity (kW) 6.0 8.0 10.0
Input (kW) 1.88 2.86 4.08
COP (W/W) 3.20 2.80 2.45
Refrigerant R32
Dimension H x W x D (mm) 1,050 x 1,010 x 370
Cord heater (W) 150