Hydro Unit
Installation Manual
– 2 –
3-EN
4-EN
Hydro Unit
4 kW, 6 kW model
Hydro Unit HWT-601XWHM3W-E HWT-601XWHM6W-E HWT-601XWHT6W-E
Back up heater capacity (kW) 3.0 6.0 6.0
Power supply
for back up heater 220-240 V ~50 Hz 220-240 V ~50 Hz 380-415 V 3N~50 Hz
for hot water cylinder
heater (option)
220-240 V ~50 Hz
Leaving water
temperature
Heating (°C) 20~55
Cooling (°C) 7~25
Dimension H x W x D (mm) 450 x 720 x 235
8 kW, 11 kW model
Hydro Unit HWT-1101XWHM3W-E HWT-1101XWHM6W-E HWT-1101XWHT6W-E HWT-1101XWHT9W-E
Back up heater capacity (kW) 3.0 6.0 6.0 9.0
Power supply
for back up heater 220-240 V ~50 Hz 220-240 V ~50 Hz 380-415 V 3N~50 Hz 380-415 V 3N~50 Hz
for hot water cylinder
heater (option)
220-240 V ~50 Hz
Leaving water
temperature
Heating (°C) 20~65
Cooling (°C) 7~25
Dimension H x W x D (mm) 450 x 720 x 235
14 kW model
Hydro Unit HWT-1401XWHM3W-E HWT-1401XWHM6W-E HWT-1401XWHT6W-E HWT-1401XWHT9W-E
Back up heater capacity (kW) 3.0 6.0 6.0 9.0
Power supply
for back up heater 220-240 V ~50 Hz 220-240 V ~50 Hz 380-415 V 3N~50 Hz 380-415 V 3N~50 Hz
for hot water cylinder
heater (option)
220-240 V ~50 Hz
Leaving water
temperature
Heating (°C) 20~65
Cooling (°C) 7~25
Dimension H x W x D (mm) 450 x 720 x 235
Hot Water Cylinder (option)
Hot Water Cylinder(option)
HWS-1501CSHM3-E
HWS-1501CSHM3-UK
HWS-2101CSHM3-E
HWS-2101CSHM3-UK
HWS-3001CSHM3-E
HWS-3001CSHM3-UK
Water volume (litter) 150 210 300
Power supply 220-240 V ~50 Hz
Max water temperature (°C) 75
Electric heater (kW) 2.7
Height (mm) 1090 1,474 2,040
Diameter (mm) 550
Material Stainless steel
Air to Water Heat Pump operating conditions
For proper performance, operate the Air to Water Heat Pump under the following temperature conditions:
Cooling operation
Outdoor temperature : 10°C to 43°C
Room temperature : 18°C to 32°C (Dry bulb temp.)
Hot water
Outdoor temperature : -20°C (-25°C*) to 43°C
Room temperature : 5°C to 32°C
Heating operation
Outdoor temperature : -20°C (-25°C*) to 25°C
Room temperature : 5°C to 32°C
(*) HWT-801(R)W-E, HWT-1101H(R)W-E, HWT-1401H(R)W-E
If Air to Water Heat Pump is used outside of the above conditions, safety protection may work.
Do not install the hydro unit and water pipes in the area where there is a risk of freezing.
Do not install the hydro unit where the outside temperature may drop below freezing point. Also, the hydro unit
may get wet in the rain.
2 Accessory parts
No. Parts name Quantity
1 Installation Manual (this document) 1
2 Owner’s Manual 1
3
Insulator for cooling
6
4 CD 1
5 TFI sensor 1
Insulator