211
No. skrameR
Fan motor
(continued)
8) Cut the binding bands for the air duct fixing fan motor
and the motor base (2 position ).
9) Loosen the two claws on the motor base.
10)Remove the fixing screws (4 positions) while holding
the fan motor so as not to fall it.
(Shoulder screw with captive washer
Φ4 × 20, 4 screws)
2. Attachment
Attach the Fan motor in the reverse process of
1. Detachment”.
Precautions when assembling the fan motor
Tighten the flange nut to 4.95 N•m (50 kgf·cm).
To prevent the fan motor leads from coming in contact
with the propeller fan ensure to adjust the length of the
fan motor lead fixing rubber so that the fan motor lead
has no slack.
Attach the fan motor lead fixing rubber to the separate
plate so that the projection is on the refrigeration cycle
side.
Ensure to bundle in the part where a binding band was
removed with a commercially available binding band.
Fix the clamp filter again in the place where it has been
removed.
Motor base
Claws
Binding bands
Air duct
Motor base
Fan motor
Work procedure