Hydro Unit
Installation Manual
– 19 –
CN1
1
2
3
4
A
B
A
B
■0-10Vinterface[HWS-IFAIP01U-E](option)
To connect the 0-10V interface
TB04 for the 0-10V interface wiring on the Hydro Unit E-BOX
Communication wiring use 2-core non-polarity wires.
Use 2-core shield wires to prevent noise trouble.
In this case, for the system grounding, close (connect) the end of shield wires, and isolate the end of terminal.
Be sure not input more than DC10V to the analogue input terminals.
The remote controller line (AB line) is available to connect maximum 2 units.
For example the header plus second remote controller or the KNX or the MODBUS or the Wireless Adapter or
the 0-10V controller.
This option allows Hydro Unit to be controlled either Setting temperatures or Capacity.
Control of Setting tempareture
DN 680 is set to “1”.
Set the input method for each setting temperature.
DN Item Selectable value (Input from)
681 Hot water setting temperature. 0:Not use AI 1: AI 1 2: AI 2 3: AI 3
682 Zone 1 setting temperature for heating. 0:Not use AI 1: AI 1 2: AI 2 3: AI 3
683 Zone 2 setting temperature for heating. 0:Not use AI 1: AI 1 2: AI 2 3: AI 3
684 Zone 1 setting temperature for cooling. 0:Not use AI 1: AI 1 2: AI 2 3: AI 3
RC : Remote controller
Allocate the temperature of 0 to 10V, and also set its resolution.
DN Item Selectable value
685
Upper limit of hot water setting temp.
(at voltage level 16)
40 to 80
Default: 65°C
689
Resolution of hot water setting temp.
(Value per voltage level)
1 to 5
Default: 5°C
686
Upper limit of Zone 1 setting temperature for heating
(at voltage level 16)
20 to 55 (65)
Default: 55°C
68A
Resolution of Zone 1 setting temperature for heating
(Value per voltage level)
1 to 5
Default: 3°C
687
Upper limit of Zone 2 setting temperature for heating
(at voltage level 16)
20 to 55 (65)
Default: 55°C
68B
Resolution of Zone 2 setting temperature for heating
(Value per voltage level)
1 to 5
Default: 3°C
688
Upper limit of Zone 1 setting temperature for cooling
(at voltage level 16)
7 to 25
Default: 20°C
68C
Resolution of Zone 1 setting temperature for cooling
(Value per voltage level)
1 to 5
Default: 1°C
*( ): HWT-110,140
Capacity direct control
DN 680 is set to “2, 3 or 4”.
DN[680] 0 1 2 3 4
AI 1
Not use
Control of Setting
tempareture
Enter settings from DN
681 to 684
Capacity direct control of
HP operation for Heating/
Cooling mode
Not use
Capacity direct control of
HP operation for Heating/
Cooling mode
AI 2
Not use
Capacity direct control of
HP operation for Hot
water mode
Capacity direct control of
HP operation for Hot
water mode
AI 3
Not use Not use Not use
Hydro Unit
Terminal block (TB04) for the remote control wiring
Locally procured
2-core, non-polarity
Size : Total Length
0.5 ~ 2.5 mm
2
: Up to 50 m
Locally procured
Size : Total Length
0.5 ~ 1.0 mm
2
: Up to 200 m
DDC
(procured locally)
1
2
3
4
CN5
1
2
3
4
CN5
1
2
3
4
CN5
0-10V interface
PCB
0-10V interface
PCB
0-10V interface
PCB
AI 1 DC0-10V (+)
AI 2 DC0-10V (+)
AI 1 DC0-10V (+)
AI 2 DC0-10V (+)
Common (-)
Common (-)
Common (-)
DN 680 = 2
Analog input enable only for Heating or cooling mode.
DN 680 = 3
Analog input enable only for Hot water mode.
DN 680 = 4
Analog input enable for Heating/Cooling and Hot water
mode.
DDC
(procured
locally)
DDC
(procured
locally)
DDC
(procured
locally)
0-10V interface
PCB
AI 1 0-10V (+)
AI 2 0-10V (+)
AI 3 0-10V (+)
Common (-)
CN5
Voltage level
(Upper limit)
[V]
Analog input
10.0
9.2
8.6
8.0
7.4
6.8
6.2
5.6
5.0
4.4
3.8
3.2
2.6
2.0
1.4
0.8
9.0
8.4
7.8
7.2
6.6
6.0
5.4
4.8
4.2
3.6
3.0
2.4
1.8
1.2
0.6
16
1
3
2
5
4
6
9
8
7
10
11
13
12
15
14
Heating / Hot water
Analog input
Analog input
No
operation
100 %
95 %
90 %
85 %
80 %
75 %
70 %
65 %
60 %
55 %
50 %
45 %
40 %
95 %
90 %
85 %
80 %
75 %
70 %
65 %
60 %
55 %
50 %
10.0
9.2
8.6
8.0
7.4
6.8
6.2
5.6
5.0
4.4
3.8
3.2
2.6
2.0
9.0
8.4
7.8
7.2
6.6
6.0
5.4
4.8
4.2
3.6
3.6
2.4
1.8
7.8
7.2
6.6
6.0
5.4
4.8
4.2
3.6
3.0
2.4
1.8
8.0
7.4
6.8
6.2
5.6
5.0
4.4
3.8
3.2
2.6
2.0
0.0
0.0
10.0
0 %
0 %
100 %
No
operation
Capacity
Demand
[V]
[V]
Capacity
Demand
Cooling
37-EN
38-EN

Other manuals for Toshiba HWT-601XWHT6W-E

Related product manuals