12 Technical parameters
Technical parameters for heat pump space heater
Climate condition : average climate
Models:
Outdoor unit HWT-401HW-E HWT-601HW-E
Indoor unit
HWT-601XWHM3W-E
HWT-601XWHM6W-E
HWT-601XWHT6W-E
Hot water cylinder - -
Air-to-water heat pump: yes yes
Water-to-water heat pump: no no
Brine-to-water heat pump: no no
Low-temperature heat pump: yes yes
Equipped with a supplementary heater: no no
Heat pump combination heater: no no
Parameters for Low-temperature application/ Medium-temperature application Low Medium Low Medium
Symbol Unit Value
Item
Rated heat output (*) P
rated
kW 5 5 6 6
Seasonal space heating energy
efficiency
ηs % 178 135 180 132
Declared
capacity for
heating for
part load
at indoor
temperature
20 °C and
outdoor
temperature
Tj
Tj = - 7 °C Pdh kW 4.4 4.0 5.3 5.0
Tj = +2 °C Pdh kW 3.0 2.5 3.4 3.4
Tj = + 7 °C Pdh kW 1.8 1.6 2.1 2.0
Tj = + 12 °C Pdh kW 1.5 1.5 1.5 1.5
Tj = bivalent
temperature
Pdh kW 4.4 4.0 5.3 5.0
Tj = operation limit
temperature
Pdh kW 4.0 3.5 5.1 4.5
Tj = - 15 °C
(if TOL < - 20 °C)
Pdh kW - - - -
Bivalent temperature T
biv
°C -7 -7 -7 -7
Cycling interval capacity for heating Pcych kW - - - -
Degradation co-efficient (**) C
dh
- 0.8 0.8 0.8 0.8
Declared
coefficient of
performance
or primary
energy ratio
for part load
at indoor
temperature
20 °C and
outdoor
temperature
Tj
Tj = - 7 °C COPd - 3.11 2.18 3.02 2.10
Tj = +2 °C COPd - 4.45 3.48 4.45 3.22
Tj = + 7 °C COPd - 5.87 4.28 6.05 4.58
Tj = + 12 °C COPd - 7.38 6.35 7.38 6.35
Tj = bivalent
temperature
COPd - 3.11 2.18 3.02 2.10
Tj = operation limit
temperature
COPd - 2.88 1.83 2.83 1.81
Tj = - 15 °C
(if TOL < - 20 °C)
COPd - - - - -
Operation limit temperature TOL °C -10 -10 -10 -10
Cycling interval efficiency P
cych
- - - - -
Heating water operating limit
temperature
WTOL °C 55 55 55 55
Power
consumption in
modes other than
active mode
Off mode P
OFF
kW 0.008 0.008 0.008 0.008
Thermostat-off mode P
TO
kW 0.040 0.040 0.040 0.040
Standby mode P
SB
kW 0.008 0.008 0.008 0.008
Crankcase heater mode P
CK
kW 0.008 0.008 0.008 0.008
Supplementary
heater
Rated heat output (*) P
sup
kW 1.0 1.5 0.9 1.5
Type of energy input 220-240V ~,50Hz 220-240V ~,50Hz
Other items
Capacity control variable variable
Sound power level, indoors/outdoors L
WA
dB 40/65 40/65 40/65 40/65
Rated air flow rate, outdoors - m
3
/h 2015 2015 2015 2015
For heat pump
combination
heater:
Declared load profile - - - - - -
Daily electricity consumption Q
elec
kWh - - - -
Water heating energy efficiency η
wh
% - - - -
contact details : ToshibaCarrierAir-conditioningEuropeSp.zo.o.,ul.Gdańska131,62-200Gniezno,Poland
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0.9.
Technical parameters for heat pump space heater
Climate condition : average climate
Models:
Outdoor unit HWT-801H(R)W-E HWT-1101H(R)W-E HWT-1401H(R)W-E
Indoor unit
HWT-1101XWHM3W-E
HWT-1101XWHM6W-E
HWT-1101XWHT6W-E
HWT-1101XWHT9W-E
HWT-1401XWHM3W-E
HWT-1401XWHM6W-E
HWT-1401XWHT6W-E
HWT-1401XWHT9W-E
Hot water cylinder - - -
Air-to-water heat pump: yes yes yes
Water-to-water heat pump: no no no
Brine-to-water heat pump: no no no
Low-temperature heat pump: yes yes yes
Equipped with a supplementary heater: no no no
Heat pump combination heater: no no no
Parameters for Low-temperature application/ Medium-temperature
application
Low Medium Low Medium Low Medium
Symbol Unit Value
Item
Rated heat output (*) P
rated
kW 8 8 9 8 11 11
Seasonal space heating energy
efficiency
η
s
% 182 142 179 142 183 138
Declared
capacity for
heating for
part load
at indoor
temperature
20 °C and
outdoor
temperature
Tj
Tj = - 7 °C Pdh kW 7.2 7.3 7.9 7.3 10.1 9.9
Tj = +2 °C Pdh kW 4.7 4.6 4.9 4.5 6.2 6.2
Tj = + 7 °C Pdh kW 3.0 3.0 3.1 3.0 4.0 3.9
Tj = + 12 °C Pdh kW 2.3 2.3 2.3 2.3 4.3 4.2
Tj = bivalent
temperature
Pdh kW 7.2 7.3 7.9 7.3 10.1 9.9
Tj = operation limit
temperature
Pdh kW 6.8 6.7 7.7 6.7 10.9 9.4
Tj = - 15 °C
(if TOL < - 20 °C)
Pdh kW - - - - - -
Bivalent temperature T
biv
°C -7 -7 -7 -7 -7 -7
Cycling interval capacity for
heating
P
cych
kW - - - - - -
Degradation co-efficient (**) C
dh
- 0.8 0.9 0.8 0.9 0.9 0.9
Declared
coefficient of
performance
or primary
energy ratio
for part load
at indoor
temperature
20 °C and
outdoor tem-
perature Tj
Tj = - 7 °C COPd - 2.72 2.12 2.59 2.12 2.68 2.21
Tj = +2 °C COPd - 4.56 3.60 4.50 3.58 4.55 3.34
Tj = + 7 °C COPd - 6.30 4.75 6.23 4.75 6.27 4.76
Tj = + 12 °C COPd - 8.40 7.00 8.40 7.00 9.16 7.27
Tj = bivalent
temperature
COPd - 2.72 2.12 2.59 2.12 2.68 2.21
Tj = operation limit
temperature
COPd - 2.62 1.90 2.42 1.89 2.63 2.01
Tj = - 15 °C
(if TOL < - 20 °C)
COPd - - - - - - -
Operation limit temperature TOL °C -10 -10 -10 -10 -10 -10
Cycling interval efficiency P
cych
- - - - - - -
Heating water operating limit
temperature
WTOL °C 65 65 65 65 65 65
Power
consumption
in modes other
than active
mode
Off mode P
OFF
kW 0.007 0.007 0.007 0.007 0.011 0.011
Thermostat-off mode P
TO
kW 0.049 0.049 0.049 0.049 0.052 0.052
Standby mode P
SB
kW 0.007 0.007 0.007 0.007 0.011 0.011
Crankcase heater mode P
CK
kW 0.000 0.000 0.000 0.000 0.000 0.000
Supplementary
heater
Rated heat output (*) P
sup
kW 1.2 1.3 1.3 1.3 0.1 1.7
Type of energy input 220-240V ~,50Hz 220-240V ~,50Hz 220-240V ~,50Hz
Other items
Capacity control variable variable variable
Sound power level, indoors/
outdoors
L
WA
dB 40/65 40/65 40/65 40/65 40/62 40/62
Rated air flow rate, outdoors - m
3
/h 3142 3142 3506 3506 4720 4720
For heat pump
combination
heater:
Declared load profile - - - - - - - -
Daily electricity consumption
Water heating energy efficiency
Q
elec
kWh - - - - - -
η
wh
% - - - - - -
contact details : ToshibaCarrierAir-conditioningEuropeSp.zo.o.,ul.Gdańska131,62-200Gniezno,Poland
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
73-EN
74-EN