FILE NO. A10-1510
SERVICE MANUAL
AIR-CONDITIONER (MULTI TYPE)
O
UTDOOR UNIT
Model name:
This service manual provides relevant explanations about new outdoor unit.
Please refer to the following service manuals for each indoor units.
MCY-MHP0404HS(J)-E/0504HS(J)-E/0604HS(J)-E
MCY-MHP0404HS-TR/0504HS-TR/0604HS-TR
MCY-MHP0404HS(J)/0504HS(J)/0604HS(J)
MCY-MHP0404HS-ID/0504HS-ID/0604HS-ID
MCY-MHP0404HS-A/0504HS-A/0604HS-A
Service Manual No.
<4-way Cassette Type>
(MMU-AP****H) A08-004
(MMU-AP***4HP*) (Made in Thailand model) SVM-13011
<2-way Cassette Type>
(MMU-AP****WH*) A10-007
<Concealed Duct Standard Type>
(MMD-AP***6BHP*) (Made in Thailand model) SVM-14069
<Slim Duct Type>
(MMD-AP024, A0274SPH*) A12-005
<Concealed Duct High Static Pressure Type>
(MMD-AP***6HP*) (Made in Thailand model) SVM-15032
<High-wall Type>
(MMK-AP***4MH*) (Made in Thailand model) SVM-09059
(MMK-AP***3H*) (Made in Thailand model) A10-034
<Console Type>
(MML-AP****NH*) (Made in Thailand model) SVM-11036
<Ceiling Type>
(MMC-AP***7HP*) (Made in Thailand model) SVM-13085
<Floor Standing Type>
(MMF-AP***6H*) A10-1420
<Other indoor units>
(MM*-AP*****H*) A10-033
A10-1510.indb1A10-1510.indb1 2016/04/0817:20:032016/04/0817:20:03
AMP Air Conditioning
www.ampair.co.uk | sales@ampair.co.uk

Table of Contents

Questions and Answers

  • J
    Jerry SmithNov 7, 2025
    Why does my Toshiba MCY-MHP0604HS-E remote controller display a check code?
    • P
      Patricia VelezNov 7, 2025
      If a check code is displayed on the Toshiba Air Conditioner remote controller, it could be due to several reasons: * The outdoor unit power might be off, so ensure it is turned on. * There might be an address setup error, where line addresses of connected indoor units are undefined, the outdoor line address doesn't match the indoor units, or indoor addresses are duplicated. In this case, set up the address again. * There could be indoor/outdoor communication circuit trouble. Check SW30 bit 2 of the outdoor unit and the communication connector between the indoor and outdoor units. * A transmission circuit trouble at the interface side (P.C.board failure) might exist, requiring replacement of the interface P.C. board. * Communication from all indoor units might be interrupted afte...
  • C
    chelsea77Nov 17, 2025
    What to do if the Toshiba MCY-MHP0604HS-E Air Conditioner displays fewer connected units after address setup?
    • K
      Kristin JonesNov 17, 2025
      If your Toshiba Air Conditioner displays a lower number of connected units than expected after address setup, and some units don't operate during a test, it could be due to: * Miswiring or unconnected communication lines between indoor units. After correcting the wiring, set up the addresses again and check the number of connected indoor units. * The indoor remote controller is not connected with a wire, or there's miswiring. Use the main indoor remote controller to start a test operation, specify the non-operating unit, and check the wiring. * Indoor remote controller communication circuit trouble, possibly due to incorrect voltage application. Use the main indoor remote controller to start a test operation, specify the non-operating unit, remove the quick connect terminal connecte...
  • J
    Jennifer McdanielDec 1, 2025
    Why is there no check code displayed on my Toshiba MCY-MHP0604HS-E Air Conditioner?
    • C
      calhounpatrickDec 1, 2025
      If there is no check code displayed on the 7-segment display of your Toshiba Air Conditioner, consider the following: * The communication line between the indoor and outdoor units might be disconnected. Modify the wiring. * The line address and indoor address might not be set. Set up the address. * The outdoor unit's power might be off in indoor group control. Turn on the power. * A group address might be set for a follower unit in individual control. Set the group address to “0” for individual control. * The power might not be turned on. Turn on the power. * The indoor remote controller might not be connected with a wire. Modify the wiring. * There might be miswiring of the indoor remote controller. Modify the wiring. * There could be indoor remote controller communicatio...

Summary

3 Wiring diagram

5 Refrigerant piping systematic drawing

6 Control outline

8 Test operation

8-4. Address setup

Procedures for setting up unit addresses.

8-5. Troubleshooting in test operation

Diagnosing issues during test operations, including check codes.

8-7. Service support function

Functions available for service and support operations.

9 Troubleshooting

9-1. Overview

General information and procedures for troubleshooting.

9-2. Troubleshooting method

Methodologies for troubleshooting based on check codes.

9-5. Diagnosis procedure for each check code

Flowcharts to guide diagnosis for specific check codes.

10 Outdoor unit parts replacement methods

12 Compressor replacement

Procedure for removing and installing the compressor.

11 P.C. board exchange procedures

11-1. Interface P.C. board replacement procedure (MCC-1639: 43 H69011)

Detailed steps for replacing the Interface P.C. board.

12 Exploded diagram; parts list

Toshiba MCY-MHP0604HS-E Specifications

General IconGeneral
BrandToshiba
ModelMCY-MHP0604HS-E
CategoryAir Conditioner
LanguageEnglish