EasyManua.ls Logo

Toshiba MMU-AP0181MH User Manual

Toshiba MMU-AP0181MH
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
OWNERS MANUAL
MANUEL DU PROPRIETAIRE
BETRIEBSANLEITUNG
MANUALE DEL PROPRIETARIO
MANUAL DEL PROPIETARIO
MANUAL DO UTILIZADOR
GEBRUIKSAANWIJZING
ÏÄÇÃÉÅÓ ×ÑÇÓÇÓ
Indoor Unit
4-way Air Discharge Cassette Type
MMU-AP0071MH, AP0091MH, AP0121MH, AP0151MH, AP0181MH,
MMU-AP0091H, AP0121H, AP0151H, AP0181H, AP0241H,
MMU-AP0271H, AP0301H, AP0361H, AP0481H
2-way Air Discharge Cassette Type
MMU-AP0071WH, AP0091WH, AP0121WH,
MMU-AP0151WH, AP0181WH, AP0241WH,
MMU-AP0271WH, AP0301WH
1-way Air Discharge Cassette Type
MMU-AP0071YH, AP0091YH, AP0121YH,
MMU-AP0152SH, AP0182SH, AP0242SH
Concealed Duct Standard Type
MMD-AP0071BH, AP0091BH, AP0121BH, AP0151BH, AP0181BH,
MMD-AP0241BH, AP0271BH, AP0301BH, AP0361BH, AP0481BH
Slim Duct Type
MMD-AP0071SPH(SH), AP0091SPH(SH), AP0121SPH(SH),
MMD-AP0151SPH(SH), AP0181SPH(SH)
Concealed Duct High Static Pressure Type
MMD-AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
Under Ceiling Type
MMC-AP0151H, AP0181H, AP0241H, AP0271H, AP0361H, AP0481H
High Wall Type
MMK-AP0071H, AP0072H, AP0091H, AP0092H, AP0121H,
MMK-AP0122H, AP0151H, AP0181H, AP0241H
Floor Standing Cabinet Type
MML-AP0071H, AP0091H, AP0121H,
MML-AP0151H, AP0181H, AP0241H
Floor Standing Concealed Type
MML-AP0071BH, AP0091BH, AP0121BH,
MML-AP0151BH, AP0181BH, AP0241BH
Floor Standing Type
MMF-AP0151H, AP0181H, AP0241H,
MMF-AP0271H, AP0361H, AP0481H
Outdoor Unit
Heat Pump Model
MCY-MAP0401HT, HT2D,
MCY-MAP0501HT, HT2D,
MCY-MAP0601HT, HT2D

Table of Contents

Other manuals for Toshiba MMU-AP0181MH

Questions and Answers:

Toshiba MMU-AP0181MH Specifications

General IconGeneral
CategoryAir Conditioner
Cooling Capacity5.0 kW
Heating Capacity5.6 kW
Power Source220-240V, 50Hz
Power Consumption (Heating)1.55 kW
Coefficient of Performance (Heating)3.61
RefrigerantR410A
Outdoor Unit Net Weight35 kg
Air Flow (Indoor Unit)10 m³/min

Summary

Safety Precautions

Warning on Installation

Instructions and warnings regarding the installation process.

Warning on Use

Precautions and warnings for operating the air conditioner.

Warning on Moving/Repair

Warnings related to moving or repairing the unit.

Caution on Installation

Cautions related to installation, drainage, earthing, and placement.

Name of Each Part

Outdoor Unit

Identification of parts for the outdoor unit.

Indoor Unit

Identification of parts for various indoor unit types.

[1-way Air Discharge Cassette Type]

Parts identification for 1-way air discharge cassette units.

[Concealed Duct Standard Type]

Parts identification for concealed duct standard type units.

Parts Name of Remote Controller

Display Section

Explanation of the indicators and symbols on the remote controller display.

Operation Section

Identification of buttons and controls on the remote controller.

Remote Control Operation Buttons

Air Volume Select Button

Function of the button for selecting airflow speed.

Timer Set Button

Button used for setting the timer.

Filter Reset Button

Button to reset the filter indicator.

Air Flow Direction and Swing Function

Controls for adjusting air direction and swing.

ON/OFF Button

Button to start or stop the unit.

Operation Select Button

Button to select the operating mode.

Set Up Temperature Button

Buttons to adjust the set temperature.

Correct Usage

Preparation

Steps to prepare the unit before initial use or data change.

Requirement

Rules to follow while operating the air conditioner.

Adjustment of Wind Direction

Caution

Caution regarding horizontal flap setting in cooling operation.

Requirement

Requirement for heating operation with horizontal discharge.

4-way Air Discharge Cassette Type

Instructions for adjusting wind direction for this type.

2-way Air Discharge Cassette Type

Setup of Air Flow Direction and Swinging Function

How to set up airflow direction and swing for 2-way cassette type.

1-way Air Discharge Cassette Type

Adjustment of Air Flow Direction Upwards/Downwards

How to adjust vertical air direction for 1-way cassette type.

Adjustment of Air Flow Direction Rightwards/Leftwards

How to adjust horizontal air direction for 1-way cassette type.

Under Ceiling Type

How to Adjust the Air Flow Direction

Steps for adjusting airflow direction for under ceiling units.

How to Adjust the Air Flow Direction, Using the Swinging Function

Steps for using the swing function to adjust airflow.

How to Stop the Louver from Swinging

Steps to stop the louver swing.

High Wall Type

Adjustment of Air Flow Direction Upwards/Downwards

How to adjust vertical airflow for high wall units.

Adjustment of Air Flow Direction Rightwards/Leftwards

How to adjust horizontal airflow for high wall units.

Setup of Air Direction and Swinging

Refer to other sections for setup of direction and swing.

Floor Standing Cabinet Type

[In Cooling Operation]

Setting airflow direction for cooling.

[In Heating Operation (For Heat-pump model only)]

Setting airflow direction for heating.

How to Change the Air Outlet Port

Procedure to change the air outlet port.

Floor Standing Type

Adjustment of Air Flow Direction Upwards/Downwards

How to adjust vertical airflow for floor standing units.

Adjustment of Air Flow Direction Rightwards/Leftwards

How to adjust horizontal airflow for floor standing units.

[In Case of Automatic Swing]

Steps for enabling and managing automatic swing.

Timer Operation

OFF Timer

Operation mode for stopping the unit at a set time.

Repeat OFF Timer

Operation mode for stopping the unit repeatedly at set intervals.

ON Timer

Operation mode for starting the unit at a set time.

Cancel of Timer Operation

How to cancel an active timer setting.

Installation

Installation Location

Guidelines for selecting an appropriate installation location.

Electric Wiring

Instructions for proper electrical wiring and earthing.

Maintenance

Cleaning of Air Filter

How to clean and reset the air filter indicator.

High Wall Type

Steps to remove and attach air filters for High Wall units.

Floor Standing Cabinet Type

Steps to remove and attach air filters for Floor Standing Cabinet units.

Floor Standing Concealed Type

Steps to remove and attach air filters for Floor Standing Concealed units.

If You Do Not Plan to Use the Unit for More Than 1 Month

Checks Before Operation

Pre-operation checks after a long period of non-use.

Hints for Economical Operation

Maintain Room Temperature at Comfortable Level

Tips on maintaining comfortable room temperature.

Clean Air Filters

Importance of clean air filters for performance.

Never Open Doors and Windows More Than What Is Necessary

Advice to conserve cool/warm air by limiting door/window opening.

Window Curtains

Using curtains for temperature control.

Air Conditioner Operations and Performance

Check Before Operation

Pre-operation checks before using the unit.

Heating Capacity (for Heat-pump model only)

Explanation of heating capacity and its dependency on outside temp.

Protection for 3 Minutes

Explanation of the 3-minute protection delay for the outdoor unit.

Re-installation

DANGER

Warning against self-re-installation and potential hazards.

Do Not Install the Air Conditioner in the Following Places

List of locations to avoid for installation.

Be Careful with Noise or Vibrations

Precautions regarding noise and vibration during installation.

When the Following Symptoms Are Found

It Is Not a Failure.

Symptoms that are normal and not indicative of a fault.

Check Again.

Common checks to perform when symptoms occur.

Confirmation and Check

Confirmation of Error History

Procedure to check past error codes and their history.

Description on Name Plate

Outline of Specifications

Table detailing the specifications for various model names.

Related product manuals