– 57 –
FILE NO. SVM-02005(1)
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove Electric parts cover.
(2-Screws ∅4 x 10L)
3) Remove the cord clamp (2-Screws ∅4 x 22L)
and disconnect the connecting cable.
4) Remove the front cabinet.
(7-Screws ∅4 x 10L with nylon washer)
Pull the front lower portion toward you, and
remove it pulling out upward.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor band.
(1-Screw ∅4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor
band.
(1-Screw ∅4 x 10L)
3) Disconnect the lead wires.
10-2. Outdoor Unit (RAS-13UA-ES)
1 Common
procedure
2 Capacitor for
compressor
3 Capacitor for
fan motor
Remove
7-Screws ∅4 x 10L
No. Part name Procedures Remarks
2-Screws ∅4 x 22L
2-Screws ∅4 x 10L
For compressor