– 59 –
FILE NO. SVM-02005(1)
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove packed valve cover and Electric
parts cover.
(2-Screws ∅4 x 10L)
3) Remove the cord clamp (2-Screws ∅4 x 22L)
and disconnect the connecting cable.
4)
Remove the upper cabinet (4-Screws ∅4 x 10L)
Pulling out upword.
5) Remove the front cabinet.
(7-Screws ∅4 x 10L)
Pull the front right portion toward you, and
remove it pulling out upward.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor
band.
(1-Screw ∅4 x 10L)
3) Disconnect the lead wires.
1) Perform the common procedure 1.
2) Remove the fixing screw and the capacitor
band.
(1-Screw ∅4 x 10L)
3) Disconnect the lead wire
10-4. Outdoor Unit (RAS-07UA-ES)
1 Common
procedure
2 Capacitor for
compressor
3 Capacitor for
fan motor
No. Part name Procedures Remarks
2-Screws ∅4 x 22L
2-Screws ∅4 x 10L
For fan motor
For compressor