FILE NO. SVM-05026
– 17 –
5-1. Indoor Unit
5-2. Outdoor Unit
5. SPECIFICATION OF ELECTRICAL PARTS
No. Parts name Model name Rating
1 SC coil L01 ADR2516-0R6TB 0.6mH, 15A
(Noise filter) L03 ADR2510-020T4B 10A, 2mH
Primary side DC280V, Secondary2 DC-DC transformer
SWT-72
side 7.0 V x 1, 12 V x 1, 17V x 2
3 Reactor CH-51-Z-T L=19mH, 10A
4 Outside fan motor
HF-240-20B-2 20W
5
G5NB-1A Coil DC12V Contact AC250V-1.5A
6
Outside air temp.
(Inverter attached) 10k (25°C)
sensor (TO sensor)
7
Heat exchanger temp.
(Inverter attached) 10k (25°C)
sensor (TE sensor)
9
JX0-6B
20A, AC250V
Terminal block (6P)
10
11
Fuse
For protection of switching power source 3.15A, AC250V
For protection of inverter input overcurrent 25A, AC250V
12
Electrolytic capacitor LLQ2G761KHUBTF 760µF, DC 400 V x 3 pieces
13
Compressor thermo. PW-2AL OFF: 125 ± 4°C, ON: 90 ± 5°C
Rectifier
14
Fan control relay
D25XB60-4001 20A, 600V
16 4-way valve coil SQ583
AC220-240V
IGBT GT20J321 20A, 600
Compressor DA89X1F-23F 3-phases 4-poles 750W
15
8
Dischenge temp.
(Inverter attached) 62k (20°C)
sensor (TD sensor)
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF-220-20-4A-1 AC Motor with 150°C thermo fuse
2 Thermo. sensor (TA-sensor) 10 k at 25°C
3 AC-AC transformer (T01) TT-10 187 - 276V, 6VA
4 Microcomputer
5 Heat exchanger sensor
10 k at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-06270 27 µ
7 Diode (DB01) KBP06M 1.5A, 420V
8 Capacitor (C50)
9 Fuse (F01) BET 3.15A 250VAC T3.15A, 250 V
10 Regulator IC (IC08) NJM7812 12VDC, 1.5A max
12 Varistor (R21, R109) 15G561K 560 V
13 Louver motor 24BYJ48 DC 12V
µPD780024AGK
LXV35VB2200MJ20 2200 µ F, 35V
11 Regulator IC (IC11) NJM7805 5VDC, 1.5A max
H, AC 0.64A