– 52 –
Table 9-4-2 Approximate value of the sensor (thermistor) resistance (TA, TC)
(= k)
9-4-3. How to Reduce the Operation Time of
the Anti-Restart Timer
Attach the diode (1S1555 or equivalent) to the rivet
inside the unit through holes on the rear of the
wireless remote control unit.
Push the START/STOP button to start operation
with the diode attached.
Fig. 9-4-1
Temperature
Sensor
Themo Sensor
0°C
35.8
10°C
20.7
20°C
12.6
25°C
10.0
30°C
7.92
Timer short diode
Wireless remote control

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba RAS-10SKH-E and is the answer not in the manual?

Toshiba RAS-10SKH-E Specifications

General IconGeneral
TypeSplit System
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
Power Supply220-240V, 50Hz
RefrigerantR410A
Energy Efficiency Ratio (EER)3.21
Coefficient of Performance (COP)3.61
Outdoor Unit Dimensions (W x H x D)660 x 530 x 240 mm
Indoor Unit Weight9 kg
Noise Level (Outdoor)48 dB(A)