<Inspection procedure>
1. Remove the front panel. (Remove 2 screws.)
2. Remove the cover of the fan motor lead wires.
3. Check AC voltage with CN31 connector while the fan motor is rotating.
NOTE :
Using a tester, measure the resistance value of each winding coil.
Use a thin test rod.
1
3
5
1
2
3
2
1
3
2
1
3
2
1
3
2
1
3
CN31
CN33
P.C. board
WHI
BLK
RED
BLK
RED
WHI
BLU
PUR
GRY
BLU
PUR
GRY
Resistance value
Position (P.C. board)
Between 3 (Black) - 1 (Red)
Between 3 (Black) - 5 (White)
249
373.3
BLK
WHI
RED
PUR
GRY
BLU
(4) Indoor fan motor automatically starts to rotate by turning on power supply
of "Judgment of Trouble by Every Symptom".
Do not disconnect the connector while the fan motor is rotating.
For P.C. board side, proceed to the item "Only indoor fan does not operate"
FILE NO. SVM-10029