2. SPECIFICATIONS
4
Unit model Indoor
RAS-10SKVR-E2
Outdoor
RAS-10SAVR-E2
Cooling capacity (kW) 2.5
Cooling capacity range (kW) 1.1 - 3.1
Heating capacity (kW) 3.2
Heating capacity range (kW) 0.9 - 4.8
Power supply 1Ph/50Hz/220-240V, 1Ph/60Hz/220-230V
Electric Indoor Operation mode
Cooling Heating
characteristic Running current (A) 0.21 - 0.19 0.24 - 0.22
Power consumption (W) 35 40
Power factor (%) 76 76
Outdoor Operation mode
Cooling Heating
Running current (A) 2.81 - 2.58 3.43 - 3.14
Power consumption (W) 563 710
Power factor (%) 91 94
Starting current (A) 3.67
COP (Cooling / Heating) 4.18 4.27 4.18/4.27
Operating Indoor High (Cooling / Heating) (dB-A) 38/39
noise Medium (Cooling / Heating) (dB-A) 33/34
Low (Cooling / Heating) (dB-A) 26/28
Outdoor (Cooling / Heating) (dB-A) 46/47
Indoor unit Unit model
RAS-10SKVR-E2
Dimention Height (mm) 275
Width (mm) 790
Depth (mm) 205
Net weight (kg) 9
Fan motor output (W) 20
Air flow rate (Cooling / Heating)
(m
3
/ min)
8.6/9.5
Outdoor unit Unit model
RAS-10SAVR-E2
Dimention Height (mm) 550
Width (mm) 780
Depth (mm) 290
Net weight (kg) 35
Compressor Motor output (W) 750
Type
Single rotary type with DC-inverter variable speed control
Model DA89X1C-23FZ2
Fan motor output (W) 43
Air flow rate (Cooling / Heating)
(m
3
/ min)
30/30
Piping Type Flare connection
connection Indoor unit Liquid side (mm)
6.35
Gas side (mm)
9.52
Outdoor unit Liquid side (mm)
6.35
Gas side (mm)
9.52
Maximum length (m) 20
Maximun charge-less length (m) 15
Maximum height difference (m) 10
Refrigerant Name of refrigerant R410A
Weight (kg) 0.8
Wiring Power supply 3 Wires: Includes earth (Outdoor)
connection Interconnection 4 Wires: Includes earth
Usable temperature range Indoor (Cooling / Heating)
(
o
C)
21 - 32/0-28
Outdoor (Cooling / Heating)
(
o
C)
-10-46/-15-24
* The specification may be subject to change without notice for purpose of improvement.