2. SPECIFICATIONS
– 4 –
Unit model Indoor
RAS-10SKVR-E2
Outdoor
RAS-10SAVR-E2
Cooling capacity (kW) 2.5
Cooling capacity range (kW) 1.1 - 3.1
Heating capacity (kW) 3.2
Heating capacity range (kW) 0.9 - 4.8
Power supply 1Ph/50Hz/220-240V, 1Ph/60Hz/220-230V
Electric Indoor Operation mode
Cooling Heating
characteristic Running current (A) 0.21 - 0.19 0.24 - 0.22
Power consumption (W) 35 40
Power factor (%) 76 76
Outdoor Operation mode
Cooling Heating
Running current (A) 2.81 - 2.58 3.43 - 3.14
Power consumption (W) 563 710
Power factor (%) 91 94
Starting current (A) 3.67
COP (Cooling / Heating) 4.18 4.27 4.18/4.27
Operating Indoor High (Cooling / Heating) (dB-A) 38/39
noise Medium (Cooling / Heating) (dB-A) 33/34
Low (Cooling / Heating) (dB-A) 26/28
Outdoor (Cooling / Heating) (dB-A) 46/47
Indoor unit Unit model
RAS-10SKVR-E2
Dimention Height (mm) 275
Width (mm) 790
Depth (mm) 205
Net weight (kg) 9
Fan motor output (W) 20
Air flow rate (Cooling / Heating)
(m
3
/ min)
8.6/9.5
Outdoor unit Unit model
RAS-10SAVR-E2
Dimention Height (mm) 550
Width (mm) 780
Depth (mm) 290
Net weight (kg) 35
Compressor Motor output (W) 750
Type
Single rotary type with DC-inverter variable speed control
Model DA89X1C-23FZ2
Fan motor output (W) 43
Air flow rate (Cooling / Heating)
(m
3
/ min)
30/30
Piping Type Flare connection
connection Indoor unit Liquid side (mm)
∅6.35
Gas side (mm)
∅9.52
Outdoor unit Liquid side (mm)
∅6.35
Gas side (mm)
∅9.52
Maximum length (m) 20
Maximun charge-less length (m) 15
Maximum height difference (m) 10
Refrigerant Name of refrigerant R410A
Weight (kg) 0.8
Wiring Power supply 3 Wires: Includes earth (Outdoor)
connection Interconnection 4 Wires: Includes earth
Usable temperature range Indoor (Cooling / Heating)
(
o
C)
21 - 32/0-28
Outdoor (Cooling / Heating)
(
o
C)
-10-46/-15-24
* The specification may be subject to change without notice for purpose of improvement.