FILE NO. SVM-04001
SERVICE MANUAL
AIR CONDITIONER
SPLIT WALL TYPE
RAS-13UKHP-ES3 / RAS-13UAH-ES3
RAS-13UKHP-AS3 / RAS-13UAH-AS3
RAS-10UKHP-ES3 / RAS-10UAH-ES3
RAS-10UKHP-AS3 / RAS-10UAH-AS3
RAS-13UKP-ES3 / RAS-13UA-ES3
RAS-13UKP-AS3 / RAS-13UA-AS3
RAS-10UKP-ES3 / RAS-10UA-ES3
RAS-10UKP-AS3 / RAS-10UA-AS3
RAS-07UKP-ES3 / RAS-07UA-ES3

Table of Contents

Questions and Answers

  • C
    Casey MaddoxAug 17, 2025
    Why won't the compressor turn on in my Toshiba RAS-10UKP-ES3 Air Conditioner, even though it should?
    • D
      Darin GrayAug 17, 2025
      The compressor in your Toshiba Air Conditioner might not turn on immediately due to a restart delay timer, which lasts for 3 minutes. This timer is also active after the power supply is turned on.
  • T
    Tammy WilliamsAug 20, 2025
    Why doesn't the compressor turn off on my Toshiba RAS-10UKP-ES3 Air Conditioner, even when it's cold enough?
    • M
      markspennyAug 20, 2025
      Your Toshiba Air Conditioner's compressor is designed to run for at least 3 minutes after being turned on, even if the room temperature reaches the point where it should turn off.
  • W
    William BrownAug 22, 2025
    What should the power supply voltage be for a Toshiba RAS-10UKP-ES3?
    • M
      Matthew StokesAug 22, 2025
      The Toshiba Air Conditioner requires a line voltage of AC 220 - 240V.
  • C
    Chelsea WheelerAug 26, 2025
    Why does the operation mode change in Automatic operation on my Toshiba RAS-10UKP-ES3 Air Conditioner?
    • B
      bellloriAug 26, 2025
      In Automatic operation, your Toshiba Air Conditioner constantly monitors the room temperature to adjust the fan speed and operation mode. The mode changes every 15 minutes based on the difference between the current room temperature and your set temperature.
  • R
    Rebecca CarlsonAug 28, 2025
    How to check cable connection between indoor and outdoor units of Toshiba Air Conditioner?
    • B
      Bobby MillerAug 28, 2025
      Ensure that the indoor and outdoor units of your Toshiba Air Conditioner are properly connected. Verify that the terminals with the same numbers are correctly matched between the units.
  • J
    James ClarkAug 31, 2025
    Why doesn't the Hi-POWER operation work on my Toshiba RAS-10UKP-ES3 Air Conditioner?
    • H
      hannahrubioAug 31, 2025
      The Hi-POWER operation on your Toshiba Air Conditioner will not function if the unit is currently in Dry operation or Fan only operation.
  • A
    Andrew ThompsonSep 2, 2025
    What does it mean when the PRE-DEF. lamp is on when Heating starts on my Toshiba RAS-10UKP-ES3?
    • M
      Mr. Samuel Fritz MDSep 3, 2025
      The PRE-DEF. lamp on your Toshiba Air Conditioner indicates that the Defrosting operation is in progress or the indoor heat exchanger temperature is low when the Heating operation starts. To prevent cold air from blowing into the room, the indoor fan motor will stop at this time.
  • H
    hallconnieSep 5, 2025
    Why does the outdoor fan motor stop when heating with my Toshiba RAS-10UKP-ES3?
    • B
      Brittany ElliottSep 6, 2025
      The outdoor fan motor on your Toshiba Air Conditioner may stop during Heating operation due to a high-temperature limit control operation when the indoor heat exchanger temperature is high.
  • M
    Mary DavisSep 8, 2025
    Why is my Toshiba RAS-10UKP-ES3 stuck on Fan only mode in Automatic operation?
    • E
      Elizabeth McguireSep 8, 2025
      If the room temperature is within ± 1°C of the preset temperature in Automatic operation, your Toshiba Air Conditioner will select Fan only operation.
  • K
    Karen LeSep 12, 2025
    Why isn't the compressor turning on and off with the thermostat in Dry mode on my Toshiba Air Conditioner?
    • C
      collinshectorSep 12, 2025
      In Dry operation, the compressor of your Toshiba Air Conditioner automatically turns on and off at regular intervals, regardless of the thermo control settings.

Summary

Air Conditioner

Split Wall Type

Specifies the type of air conditioner covered in the manual.

Specifications

Construction Views

Provides detailed diagrams of the unit's construction.

Operation Description

Outline of Air Conditioner Control

Explains the basic control logic and components of the air conditioner.

Installation Procedure

Safety Cautions

Highlights critical safety precautions for installation.

8-1. Safety Cautions

Highlights critical safety precautions for installation.

8-2. Installation Diagram of Indoor and Outdoor Units

Provides diagrams for positioning indoor and outdoor units.

8-5-2. Refrigerant piping connection

Detailed steps for connecting refrigerant pipes.

8-5-3. Evacuating

Procedure for evacuating air from the refrigerant system.

Specification of Electrical Parts

Troubleshooting Chart

9-1. Troubleshooting Procedure

General steps for troubleshooting.

9-4. Self-Diagnosis by Remote Control

How to use the remote for self-diagnosis.

9-5. Troubleshooting Flowcharts

Flowcharts to guide troubleshooting steps.

Part Replacement

10-1. Indoor Unit

Procedures for replacing parts of the indoor unit.

10-2. Outdoor Unit

Procedures for replacing parts of the outdoor unit.

Exploded Views and Parts List

11-1. Indoor Unit (E-Parts Assy) (For Heat pump model)

Exploded view and parts list for the indoor unit (heat pump).

11-2. Indoor Unit (E-Parts Assy) (For Cooling model)

Exploded view and parts list for the indoor unit (cooling).

11-3. Outdoor Unit (RAS-13 UAH-ES3, RAS-13 UAH-AS3)

Exploded view and parts list for specific outdoor units.

11-4. Outdoor Unit (RAS-10 UAH-ES3, RAS-10 UAH-AS3)

Exploded view and parts list for specific outdoor units.

11-5. Outdoor Unit (RAS-13 UA-ES3, RAS-13 UA-AS3)

Exploded view and parts list for specific outdoor units.

11-6. Outdoor Unit (RAS-10 UA-ES3, RAS-10 UA-AS3)

Exploded view and parts list for specific outdoor units.

11-7. Outdoor Unit (RAS-07 UA-ES3)

Exploded view and parts list for a specific outdoor unit.

Toshiba RAS-10UKP-ES3 Specifications

General IconGeneral
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
RefrigerantR410A
Power Supply220-240V, 50Hz
Indoor Unit Weight9 kg
Energy Efficiency Ratio (EER)3.21
Coefficient of Performance (COP)3.61