SEER | 6.1 |
---|---|
Refrigerant | R32 |
Power Supply | 220-240 V, 50 Hz |
Indoor Unit Weight | 9 kg |
Air Flow (Indoor Unit) | 10.2 m³/min |
Detailed diagrams and dimensions for the indoor unit, including installation aspects.
Detailed diagrams and dimensions for the outdoor unit, including installation aspects.
Electrical wiring schematic for specific Toshiba air conditioner models.
Electrical wiring schematic for specific Toshiba air conditioner models.
Electrical wiring schematics for various RAS-13/10UKP/UA/PX/UAX models.
Detailed specifications for electrical components within the indoor unit.
Detailed specifications for electrical components within the outdoor unit.
Detailed specifications for electrical components within the outdoor unit.
Detailed specifications for electrical components within indoor units.
Detailed specifications for electrical components within the outdoor unit.
Detailed specifications for electrical components within the outdoor unit.
Detailed specifications for electrical components within the outdoor unit.
Diagram illustrating the refrigeration cycle for specific air conditioner models.
Diagram illustrating the refrigeration cycle for specific air conditioner models.
Diagram illustrating the refrigeration cycle for specific air conditioner models.
Diagram illustrating the refrigeration cycle for specific air conditioner models.
Diagram illustrating the refrigeration cycle for specific air conditioner models.
Diagram illustrating the refrigeration cycle for specific air conditioner models.
Block diagram showing the control system for indoor and outdoor units.
Block diagram illustrating control system logic for various air conditioner models.
Overview of how the air conditioner's control system operates.
Explanation of the electrical circuits governing air conditioner operations.
Details on activating and the functionality of the high power mode.
Mechanism to prevent excessive pressure by controlling heat exchanger temperature.
Mechanism to prevent indoor heat exchanger freezing.
Procedure and conditions for the defrost operation in heating mode.
Control logic to prevent exceeding specified input current limits.
How to enable and use the automatic restart feature after power interruption.
Information on the filter check indicator and how to reset it.
Essential safety precautions and warnings for qualified personnel during installation.
Graphical guide for positioning and installing indoor and outdoor units.
List and details of optional parts required for installation.
Guidelines for selecting an appropriate location for indoor unit installation.
Guidelines for selecting an appropriate location for outdoor unit installation.
Procedure to set the remote control selector switch for multi-unit installations.
Steps to follow for diagnosing and resolving air conditioner issues.
Fundamental checks to perform before detailed troubleshooting.
Initial assessment of problems based on unit symptoms and indicators.
Using the remote control to access diagnostic codes and identify faults.
Visual guides to systematically diagnose and resolve specific operational problems.
Specific steps to diagnose and fix issues related to the remote control.
Step-by-step guide for replacing internal components of the indoor unit.
Step-by-step guide for replacing internal components of the outdoor unit.
Visual breakdown of indoor unit components with part numbers.
Detailed exploded diagram and parts list for the indoor unit.
Visual breakdown of outdoor unit components with part numbers.
Visual breakdown of outdoor unit components with part numbers.
Visual breakdown of outdoor unit components with part numbers.
Visual breakdown of outdoor unit components with part numbers.
Visual breakdown of outdoor unit components with part numbers.
Visual breakdown of outdoor unit components with part numbers.