Important safety warnings and precautions to be observed during installation.
Detailed steps for connecting refrigerant pipes, including cutting, flaring, and tightening torque.
Procedure for removing air from the refrigerant pipes using a vacuum pump.
Method for checking refrigerant gas leaks using a leak detector or soap water.
Instructions on accessing and interpreting error codes displayed on the remote control.
Flowchart to diagnose and resolve issues where the unit does not turn on or operate.
Flowchart to diagnose why the outdoor unit is not functioning.
Flowchart to diagnose issues specifically related to the compressor not operating.
Flowchart to diagnose why the outdoor fan motor is not operating.
Flowchart for diagnosing issues with the 4-way valve during heating operation.
Flowchart to diagnose why the indoor fan motor is not operating.
Flowchart for diagnosing and resolving problems with the remote control and its communication.