5
FILE NO. SVM-04001
MODEL
RAS-07UKP-ES3
RAS-07UA-ES3
ITEM
Cooling
Capacity
220V
240V
kW 2.15 2.18
Phase 1
ı
Power source V 220 240
Hz 50
Power consumption kW 0.66 0.68
Power factor % 97 90
Running Indoor A 0.15
current Outdoor A 3.10 3.15
Starting current A 12
Moisture removal lit/h 0.8
Noise
Indoor (H/M/L) dB 38/32/26
Outdoor (220-240V) dB 44 45
Refrigerant
Name of refrigerant R410A
Rated amount kg
0.65
Refrigerant control Capillary tube
Gas side size mm 9.52
Connection type Flare connection
Liquid side size mm 6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 10*
1
(One way)
Maximum height
difference
INDOOR UNIT
RAS-07UKP-ES3
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h
570
Air volume Medium fan m
3
/h
460
Low fan m
3
/h 340
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-07UA-ES3
Height mm 530
Dimensions Width mm 660
Depth mm 240
Net weight kg
27
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 1420 1520
Fan motor output W
30
Compressor
Model PA79X1T-4FZ5
Output W 605
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43