− 5 −
MODEL
RAS-07UKP-ES4
RAS-07UA-ES4
ITEM
Cooling
Capacity
220V
240V
kW 2.23 2.27
Phase 1
∅
Power source V 220 − 240
Hz
50
Power consumption kW 0.68 0.70
Power factor % 98 96
Running Indoor A 0.15
current Outdoor A 3.00 2.90
Starting current A 13
Moisture removal lit/h 0.8
Noise
Indoor (H/M/L) dB 38/32/26
Outdoor (220-240V) dB 44 45
Refrigerant
Name of refrigerant R410A
Rated amount kg
0.63
Refrigerant control Capillary tube
Gas side size mm ∅9.52
Connection type Flare connection
Liquid side size mm ∅6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 10*
1
(One way)
Maximum height
difference
INDOOR UNIT
RAS-07UKP-ES4
Height mm 275
Dimensions Width mm 790
Depth mm 208
Net weight kg 10
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m
3
/h
570
Air volume Medium fan m
3
/h
460
Low fan m
3
/h 340
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-07UA-ES4
Height mm 530
Dimensions Width mm 660
Depth mm 240
Net weight kg
27
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m
3
/h 1420 1520
Fan motor output W
30
Compressor
Model PA82X1C-4DZDN
Output W 605
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43
m
5
m
FILE NO. SVM-05020