Do you have a question about the Toshiba RAS-13UAX2 and is the answer not in the manual?
Cooling Capacity | 3.5 kW |
---|---|
Heating Capacity | 4.0 kW |
Power Supply | 220-240V, 50Hz |
Refrigerant | R410A |
Type | Split System |
Noise Level (Outdoor) | 50 dB(A) |
Detailed dimensions and features of the indoor unit.
Detailed dimensions and features of the outdoor unit.
Wiring schematics for specific indoor/outdoor unit models.
List of electrical components for indoor units.
Electrical parts for specific indoor unit models.
Electrical parts for specific outdoor unit models.
Refrigeration cycle diagrams for specific model units.
Control block diagrams for specific model groups.
Overview of the air conditioner's control system.
Details on the electronic circuits controlling operations.
How the unit operates in fan-only, cooling, and dry modes.
How the unit operates in heating and automatic modes.
Hi POWER, High-Temp Limit, and Low-Temp Limit controls.
Procedure for melting ice during heating operation.
Control to prevent excess current to outdoor fan.
Functionality for automatic unit restart after power loss.
Indicator for filter maintenance and its reset procedure.
Critical safety warnings before installation.
Visual guide for the physical installation of units.
General installation steps and optional parts.
List of included accessories and installation components.
Guidelines for installing the indoor unit.
Instructions for electrical connections and power supply.
Steps for installing refrigerant piping and drain hoses.
How to securely mount the indoor unit and set up drainage.
Guidelines for installing the outdoor unit.
Proper procedures for connecting refrigerant pipes.
Process for removing air from the refrigerant system.
Connecting outdoor unit wiring and configuring remote control.
Miscellaneous installation checks and topics.
Step-by-step guide to diagnose issues and initial checks.
Initial assessment of symptoms and self-diagnosis methods.
Using the remote control for error code diagnosis.
Visual flowcharts for diagnosing specific operational failures.
Troubleshooting flow for power issues post-PC board replacement.
Diagnostic steps when the outdoor unit fails to run.
Troubleshooting steps if only the compressor fails to operate.
Troubleshooting steps if only the outdoor fan fails to operate.
Diagnosing failure of the 4-way valve in heating mode.
Troubleshooting steps if only the indoor fan fails to operate.
Steps to troubleshoot remote control and indoor PC board issues.
Procedures for inspecting the main printed circuit board.
Method to reduce the restart delay timer duration.
Diagram showing the layout of components on the PC board.
Procedures for replacing parts within the indoor unit.
Procedures for replacing parts within the outdoor unit.
Exploded view and parts list for indoor unit electrical components.
Exploded view and parts list for the indoor unit assembly.
Exploded view and parts list for a specific outdoor unit model.
Exploded view and parts list for a specific outdoor unit model.
Exploded view and parts list for a specific outdoor unit model.
Exploded view and parts list for a specific outdoor unit model.
Exploded view and parts list for a specific outdoor unit model.
Exploded view and parts list for a specific outdoor unit model.