53
FILE NO. SVM-03004(1)
9-5-2. Power can not be turned on after replacing indoor P.C. board
<Checking Procedure>
Connect the AC
Power supply
Does the OPERATION
lamp blink?
Is it wired as shown
in Figure below?
Return the wiring of the
power relay is returned to
the normal procedure.
To the paragraph of
No Power turns on.
YES
NO NO
YES
RAS-10UKHP-E2
RAS-13UKHP-E2
Double winding
Indoor
terminal
block
Power
terminal
block
Black
White
Blue
Brown
RY01
P.C. board
CN31
T02
Bind Band
Indoor
terminal
block
Power
terminal
block
Black
White
Blue
Brown
RY01
P.C. board
CN31
T02
1 234
NL
1 234 NL

Table of Contents