EasyManua.ls Logo

Toshiba RAS-13UAX2 - SPECIFICATION OF ELECTRICAL PARTS; Indoor Unit Electrical Parts

Toshiba RAS-13UAX2
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 12 –
FILE NO. SVM-03004(1)
4. SPECIFICATION OF ELECTRICAL PARTS
4-1.Indoor Unit (RAS-13UKHP-E2, RAS-10UKHP-E2)
No. Parts name Type Specifications
1 Fan motor (for indoor) MMF-240-20-4A-1 AC Motor with 135°C thermo fuse
2 Thermo sensor (TA-sensor) ——— 10k at 25°C
3 Switching transformer (T01) SWT-47
4 Microcontroller unit (IC30) TMP87CM40AN
5 Heat exchanger sensor
——— 10k at 25°C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB01) D3SBA60 4A, 60 V
8 Capacitor (C02) KMH400VSSN47M22S 47µF, 400 V
9 Fuse (F01) TSCR6.3A T6.3A, 250VAC
10 Varistor (R21, R22) 15G561K 560 V
11 Resistor (R01) RF-2TK5R6 5.6, 2 W
12 Louver motor MP24GA 12VDC
13 Relay (Comp., RY01) DI12D1 Rating 20A/AC250 V, 12VDC
14 Relay (Fan, RY03) G5N-1A Rating 3A/AC250 V, 12VDC
15 Relay (Solenoide, RY04) G5N-1A Rating 3A/AC250 V, 12VDC
4-2.Outdoor Unit (RAS-13UAH-E2)
No. Parts name Type Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220 – 240 V, 50Hz
1 Compressor PH170T2-4L2 Winding resistance () C-R C-S
(at 20°C) 2.22 3.04
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50Hz
2 Fan motor (for outdoor) HF-240-42A Winding resistance () Red-Black White-Black
(at 20°C) 176.2 290.5
3
Running capacitor
DS45115CBPQC AC 450 V, 1.5µF
(for fan motor)
4
Running capacitor
DS371356CPN AC 370 V, 35µF
(for compressor)
5
Solenoid coil
VHV-01AJ503C1 AC 220 – 240 V, 50Hz
(for 4-way valve)
6 Overload relay JMRA99257-9200 U/T : 8.0A (80°C), OPEN : 145±5°C, CLOSE : 75±11°C

Table of Contents