− 23 −
5-5. RAS-07UKP-ES4 / RAS-07UA-ES4
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Standard 1.00 13.0 High 27/19 35/24
Cooling Overload 1.14 18.0 High 32/23 43/26
Low temperature 0.75 2.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Propeller fan
Outdoor unit
PA82X1C-4DZDN
Cooling
Mark( )means check points of Gas Leak.
O.D.:9.52mm O.D.:6.35mm
Cooling
Packed valve
(∅9.52)
Packed valve
(∅6.35)
0.39m
(Connecting pipe)
∅9.52
0.49m
(Connecting pipe)
∅6.35
T1
P
Refrigerant
R-410A : 0.63 kg.
Heat exchanger
Capillary tube
∅1.2x550l
Heat exchanger
FILE NO. SVM-05020