Do you have a question about the Toshiba RAS-13YA-ES and is the answer not in the manual?
Details the dimensions and mounting of the indoor unit.
Details the dimensions and mounting of the outdoor unit.
Lists electrical components and specifications for the indoor unit.
Lists electrical components and specifications for the outdoor unit.
Illustrates the refrigerant flow for specific models.
Illustrates the refrigerant flow for specific models.
Illustrates the refrigerant flow for specific models.
Illustrates the refrigerant flow for specific models.
Describes the operation mode for fan-only functionality.
Details the control logic for cooling mode.
Explains how to control the louvers' position.
Details the control logic for dry mode.
Details the control logic for heating mode.
Describes the automatic selection of operating modes.
Explains the energy-saving mode operation.
Details control to prevent exceeding current limits.
Control to prevent high indoor heat exchanger temperatures.
Control to prevent freezing of the indoor heat exchanger.
Controls indoor fan speed to prevent cold air blowing.
Describes the defrost cycle logic and conditions.
Explains the automatic restart feature after power interruption.
Provides essential safety warnings for installation.
Diagram showing indoor and outdoor unit installation layout.
Lists optional parts required for installation.
Lists the parts included with the unit for installation.
Guidance on selecting the installation place for the indoor unit.
Details electrical connection requirements and precautions.
Instructions for connecting the unit's wiring.
Procedures for installing refrigerant pipes and drain hoses.
Instructions for proper drainage setup.
Guidance on selecting the installation place for the outdoor unit.
Lists the tools needed for installation work.
Details on connecting the refrigerant pipes.
Procedure for evacuating air from the refrigerant system.
Procedure for testing for refrigerant gas leaks.
Instructions for performing a test run of the unit.
Instructions for setting the auto restart function.
Basic checks to perform before detailed troubleshooting.
Initial assessment of potential fault locations.
Step-by-step guides for diagnosing and resolving issues.
Procedures for inspecting and testing the printed circuit board.
How to shorten the operation time of the anti-restart timer.
Procedures for replacing parts of the indoor unit.
Procedure for replacing the microcomputer.
Procedures for replacing parts of the outdoor unit.
Exploded view of indoor unit components.
Exploded view of indoor unit components.
Exploded view of outdoor unit components.
| Category | Air Conditioner |
|---|---|
| Cooling Capacity | 3.5 kW |
| Heating Capacity | 4.0 kW |
| Power Supply | 220-240V, 50Hz |
| Weight of Indoor Unit | 9.5 kg |
| Weight (Indoor Unit) | 9.5 kg |
| Noise Level (Indoor) | 24 dB |











