EasyManua.ls Logo

Toshiba RAS-16SKV2-E1 - Specifications of Electrical Parts

Toshiba RAS-16SKV2-E1
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-1. Indoor Unit
No. Parts name Type Specifications
MF-340-30-3 DC 340V, 30W
2
Room temp. sensor (TA-sensor)
( - )
10k at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
( - )
10k at 25°C
4 Louver motor
24BYJ48-HT
Output (Rated) 1W, 16 poles, DC12V
6-2. Outdoor Unit
1
Fan motor (for indoor)
No. Parts name Type Specifications
CH-57 L = 10mH, 16A
2 Outdoor fan motor ICF-140-43-4R DC140V, 43W
3
Suction temp. sensor (TS sensor)
(Inverter attached) 10k (25°C)
4 Discharge temp. sensor (TD sensor)
(Inverter attached) 62k (20°C)
5 Outside air temp. sensor (TO sensor)
(Inverter attached) 10k (25°C)
Heat exchanger temp. sensor (TE sensor)
(Inverter attached)
10k (25°C)
Reactor
1
20A, AC250V
DA131S1B-31FZ
CAM-MD12TCTH-5
STF
3-phases 4-poles 1100W
DC12V
AC220-240V
Coil for 4-way valve
COIL FOR P.M.V.
Compressor
Terminal block (5P)7
8
9
10
6. SPECIFICATIONS OF ELECTRICAL PARTS
FILE NO. SVM-11029
18
6

Table of Contents

Related product manuals