– 17 –
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1
2
3
4
Parts name
Fan motor
(for indoor)
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Louver motor
Type
AFS-220-31-4B
( — )
( — )
MSBPC20F04
Specifications
AC 220V, 31W
10kΩ at 25°C
10kΩ at 25°C
4 phase, 16 pole, DC12V
No.
1
2
3
4
5
6
7
Parts name
Reactor
Outdoor fan motor
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
Terminal block (5P)
Compressor
Model name
CH-69-Z-T
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA131S1B-31FZ
CAM-MD12TCTH-5
Rating
L = 19mH, 10A
DC140V, 43W
10kΩ (25°C)
62kΩ (20°C)
10kΩ (25°C)
20A, AC250V
3-phases 4-poles 1100W
DC12V
FILE NO. SVM-12053
8
Coil for PMV
(18N3KCV)