Be sure to refer to the wiring system diagram labeled inside the front
panel.
Check local electrical cords and also any speci c wiring instructions or
limitations.
NOTE
Use stranded wire only.
Wire type : More than 1.5 mm² (H07RN-F or 60245 IEC66) or 1.3 mm²
(AWG-16)
CAUTION
1
2
3
Cord clamp
Terminal block
Terminal cover
Screw
Earth line
Screw
Connecting cable
Earth line
Connecting cable
Stripping length of the connecting cable
about 15 cm
110 mm
80 mm
20 mm
10 mm
1. Open the air inlet grille upward.
2. Securely remove four screws at the front panel.
3. Slightly open the lower part of the front panel then pull the upper part of
the front panel toward you to remove it from the rear plate as shown on
gure 1.
4. After removing the front panel, remove the screws and Display unit from
the unit as shown on gure 2 then open the front cover of Display unit
as shown on gure 3.
5. Arrange the control wire as detail and speci cation as shown on gure 4.
6. Securely connect the control wire to terminal of Display unit board as
shown on gure 5 (tighten rmly but not over 0.12 N·m (0.01 kgf·m)).
7. Set the control wire throughout at slot on front cover of Display unit then
reassembly Display with main casing by reverse process of gure 2 and
3. Make sure the control wire must not be pressed by front and rear
cover of Display unit.
8. Set the control wire out from indoor unit same portion as power supply
and connecting cable as shown on gure 6.
9. Reassembly the indoor unit by reverse process of 1 to 3.
Indoor unit
Control wire
Remote controller
How to Connect Remote Controller
for Wire Operation
For indoor unit
2
1
3
Air inlet grille
Front panel
1
Display board
23
Display unit
Remove screw
1. Remove cover of remote controller by sliding down and take it out.
2. If batteries are exist, please take them out. The combination of using
wire controller and batteries may cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver break the polyester
sheet as shown on gure 7.
4. Insert control wire from rear side of remote controller as shown on
gure 8.
5. Fix control wire which arrange as shown on gure 9 and ! to terminal
by provided screws (tighten rmly but not over 0.25 N·m (0.03 kgf·m)).
6. Set control wire through gutter way at rear side of remote controller as
shown on gure ".
7. Fix provided screw (Ø3.1×16L) on the wall to hang remote controller as
shown on gure #.
8. Mark and arrange hole for x below screw (Ø3.1×25L) as shown on
gure #.
9. Assembly battery cover which provided with accessory bag then use
provide screw (Ø3.1×25L) to x battery cover together with wall as
shown on gure $ (tighten rmly but not over 0.15 N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
For remote controller
CAUTION
• Be sure to install control wire along
the wall so that there is no slack and
x remote controller on the wall.
* Wire size 28-22 AWG (0.08-0.32 mm
2
)
Outer diameter not over 4.7 mm, control wire
length less than 30 m.
70 mm
5 mm
4
6
5
Terminal
Control wire
Control wire out position
Control wire through out position
Tighten rmly but
not over 0.12 N·m
(0.01 kgf·m)
Control wire
78
Polyester sheet
close hole for insert
control wire
Control wire
9!
Control wire
Terminal
* Wire size 28-22 AWG (0.08-0.32 mm
2
)
Outer diameter not over 4.7 mm,
control wire length less than 30 m.
30 mm
10 mm
Tighten rmly but not over
0.25 N·m (0.03 kgf·m)