:Operatethepresetoperation.
AUTO RESTART OPERATION
15
Toautomaticallyrestarttheairconditionerafterthepowerfailure(Powerofthe
unitmustbeon.)
Setting
1.PressandholdtheRESETbuttonontheindoorunitfor3secondstosetthe
operation.(3beepsoundandOPERATIONlampblink5time/secfor
5seconds)
2.PressandholdtheRESETbuttonontheindoorunitfor3secondstocancel
theoperation.(3beepsoundbutOPERATIONlampdoesnotblink)
• IncaseofONtimerorOFFtimeareset,AUTORESTARTOPERATION
doesnotactivate.
Tooperateatsuperlowfanspeedforquietoperation(exceptinDRYmode)
Press
QUIET
:Startandstoptheoperation.
Note:Undercertainconditions,QUIEToperationmaynotprovideadequate
coolingorheatingduetolowsoundfeatures.
QUIET OPERATION
16
Forcomfortablesleep,automaticallycontrolairowandautomaticallyturnOFF.
Press
COMFORT
SLEEP
:Select1,3,5or9hrsforOFFtimeroperation.
Note: Thecoolingoperation,thesettemperaturewillincreaseautomatically
1degree/hourfor2hours(maximum2degreesincrease).Forheating
operation,thesettemperaturewilldecrease.
COMFORT SLEEP OPERATION
17
OPERATION AND PERFORMANCE
21
1.Three-minuteprotectionfeature:Topreventtheunitfrombeingactivatedfor
3minuteswhensuddenlyrestartedorswitchedtoON.
2.Preheatingoperation:Warmuptheunitfor5minutesbeforeblowingwarmair.
3.Warmaircontrol:Whentheroomtemperaturereachesthesettemperature,
thefanspeedisautomaticallyreducedandtheoutdoorunitwillstop.
4.Automaticdefrosting:Fanswillstopduringdefrostoperation.
5.Heatingcapacity:Heatisabsorbedfromoutdoorandreleasedintotheroom.
Whentheoutdoortemperatureistoolow,useanotherrecommendedheating
apparatusincombinationwiththeairconditioner.
6.Considerationforaccumulatedsnow:Selectthepositionforoutdoorunitwhere
itwillnotbesubjectedtosnowdrifts,accumulationofleavesorotherseasonal
debris.
7.Someminorcrackingsoundmayoccurwhenunit operating.Thisisnormal
becausethecrackingsoundmaybecausedbyexpansion/contractionofplastic.
Note:Item2to6forHeatingmodel
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature
Room
Temperature
Heating –10°C~24°C Lessthan28°C
Cooling 15°C~46°C 21°C~32°C
Dry 15°C~46°C 17°C~32°C
The unit does not operate.
Cooling or Heating is abnormally low.
•
Thepowermainswitchisturnedoff.
• Thecircuitbreakerisactivatedto
cutoffthepowersupply.
• Stoppageofelectriccurrent.
• ONtimerisset.
• Theltersareblockedwithdust.
•Thetemperaturehasbeenset
improperly.
•Thewindowsordoorsareopened.
•Theairinletoroutletoftheoutdoor
unitisblocked.
•Thefanspeedistoolow.
•
TheoperationmodeisFANorDRY.
TROUBLESHOOTING (CHECK POINT)
22
Tostartthesleeptimer(OFFtimer)operation
Press
SLEEP
:Select1,3,5or9hrsforOFFtimeroperation.
SLEEP TIMER OPERATION
18
REMOTE CONTROL A-B SELECTION
23
Toseparateusingofremotecontrolforeachindoorunitincaseof2air
conditionersareinstallednearly.
Remote Control B Setup.
1.PressRESETbuttonontheindoorunittoturntheairconditionerON.
2.Pointtheremotecontrolattheindoorunit.
3.Pushandhold
CHK●
buttonontheRemoteControlbythetipofthepencil.
“00”willbeshownonthedisplay.
4.Press
MODE
duringpushing
CHK●
.“B”willshowonthedisplayand“00”
willdisappearandtheairconditionerwillturnOFF.TheRemoteControlBis
memorized.
Note: 1.Repeatabovesteptoreset
RemoteControltobeA.
2.RemoteControlAhasnot“A”
display.
3.DefaultsettingofRemote
ControlfromfactoryisA.
SELF CLEANING OPERATION (COOL AND DRY
OPERATION ONLY)
20
Toprotectbadsmellcausedbythehumidityintheindoorunit.
1.Ifthe
buttonispressedonceduring“Cool”or“Dry”mode,thefanwillcontinue
torunforother20minutes,thenitwillturnoffautomatically.Thiswillreduce
themoistureintheindoorunit.
2.Tostoptheunitimmediately,pressthe
more2timeswithin30seconds.
Note:
• SELFCLEANINGoperationisdefaultsettingfromfactory.
• Tocancelthisfunction,pressandholdtheresetbuttonontheindoorunitfor
20seconds.
TheSELFCLEANINGoperationwillbecancelled.(5beepsoundbut
OPERATIONlampdoesnotblink)
• Dothesametosetthisfunctionagain.(5beepsoundandOPERATIONlamp
blink5times/secfor5seconds)
• AUTORESTARToperationwillbecancelledbysettingorcancellationof
SELFCLEANINGoperation.Setitagainifneccessary.
Firstly,turnoffthecircuitbreaker.
Filter Reset
FILTERlamplightson;theltermustbecleaned.
Toturnoffthelamp,pushtheRESETbuttonontheindoorunitortheFILTERbutton
ontheremotecontrol.
Indoor Unit and Remote Control
• Cleantheindoorunitandtheremotecontrolwithawetclothwhenneeded.
• Nobenzine,thinner,polishingpowderorchemically-treatedduster.
Cleaning the air ionizer (Once every six months)
1.Turnoffairconditionerusingremotecontrolandpowersupply.
2.Fullyopentheverticalairowlouversbyhand.
3.Useatoothbrushtorubtheendsofmetalpin
threeorfourtimes.
Note: Donotusecottonswabsorotherobjects
withuff.
Evenbefore6monthssincelastcleaning,
cleantheairionizerifitisdirty.
Cleaning the plasma air purier unit (About 1000 hours performed)
1.Turnoffairconditionerusingremotecontrolandpowersupply.
2.Takeouttheairinletgrille(Seedetailininstallationmanual).
3.Takeouttheplasmaairpurierbygraspthehandle,andthepullitout
4.Soakinhotwaterat40°Cto50°Cforabout10to15minutesandrubup,
down,left,rightandrubsurfacegentlywithasponge.
5.Allowtodrythoroughlyintheshade.
6.Attachtheplasmaairpurierbygraspthehandleand
insertintotherightandleftguiderails.
7.Pressbothendsoftheplasmaairpurieruntilthe
protrusionsonbothsidesoftheplasmaairpurier
arecompletelyinsertd.
8.Attachtheairlter,andthenclosetheairinletgrille.
MAINTENANCE
19