– 76 –
FILE NO. SVM-09036
1) Perform the common procedure 1
2) Remove the capacitor band. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (1 screw ∅4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure 1
2) Remove the fixing screw. (2 screws ∅4 x 18L)
3) Disconnect the lead wires from the terminal.
2 Running
capacitor
for compressor
3 Running
capacitor
for fan motor
4 Magnetic
contactor
5
Procedures
Remarks
Part name
No.
Running capacitor for
compressor
Running capacitor
for fan motor
Magnetic
P.C. Board
Transformer
1) Perform the common procedure 1
2) Remove the fixing screw. (2 screws ∅4 x 10L)
3) Disconnect the housing from the P.C. Board.
Transformer
1) Perform the common procedure 1
2) Disconnect the lead wires from the P.C. Board.
3) Remove P.C.Board after unhooking 4 clams.
Transformer
( For 18, 24 Heating )