– 22 –
FILE NO. SVM-03010(1)
4-10. Outdoor Unit (RAS-18UAX2-T2)
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH210T2-4L7 Winding resistance () C-R C-S
(at 20°C) 1.07 2.20
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) KFG6-71SB5P-T Winding resistance () Red-Black White-Black
(at 20°C) 64.4 127.4
3
Running capacitor
451355KQ AC 450 V, 3.5µF
(for fan motor)
4
Running capacitor
371356JCR AC 420 V, 35µF
(for compressor)
5 Magnetic contactor A35 220 – 240 V, 50 Hz