EasyManua.ls Logo

Toshiba RAS-18UAX3 - 4. SPECIFICATION OF ELECTRICAL PARTS; 4-1. Indoor Unit

Toshiba RAS-18UAX3
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FILE NO. SVM-04032
– 18
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit
No. Parts name Type Specifications
1 Fan motor (for indoor) AFP-220-50-4A Output (Rated) 50W, 220 240V
2 Thermo sensor (TA-sensor) ——— 10k at 25°C
3 DC-DC transformer (T01) SWT-47 DC 390V, Secondary DC 12V, 7V
4 Microcomputer TMP87CM40AN
5
Heat exchanger sensor
——— 10k at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-R07190 19mH, AC0.7A
7 Diode (DB01) D3SBA60 4A, 600V
8 Capacitor (C02) KMH400VSSN47M22S 47µF, 400V
9 Fuse (F01) TSCR T6.3A, 250V
10 Varistor (R21, R22) 15G561K 560V
11 Resistor (R01) RF-2TK5R6 5.6, 2W
12 Louver motor MP35EA12
Output (Rated) 2W, 6poles, 4
phase,
DC 12V
4-2. Outdoor Unit (RAS-18UAH-E3)
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH250X3-4LM Winding resistance () C-R C-S
(at 20°C) 2.29 1.22
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) KFG6-71SB5P-T3 Winding resistance () Red-Black White-Black
(at 20°C) 64.4 127.4
3
Running capacitor
451205KQ AC 450 V, 2µF
(for fan motor)
4
Running capacitor
371456JCR AC 370 V, 45µF
(for compressor)
5
Solenoid coil
VHV (STF) AC 220 – 240 V
(for 4-way valve)
6 Thermo sensor TE / TD 10 k at 25°C / 50 k at 25°C
7 Magnetic contactor
CLK-26J
220 240 V, 50 Hz
8 Transformer TT-05 220 – 240 V
9 Microcontroller TMP47C840N
10 Varistor (R73, R74, R86) 15G471K 470 V
11 Fuse (F01) MT3 T6.3 A, 250 V

Table of Contents