FILE NO. SVM-04032
– 18 –
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit
No. Parts name Type Specifications
1 Fan motor (for indoor) AFP-220-50-4A Output (Rated) 50W, 220 − 240V
2 Thermo sensor (TA-sensor) ——— 10kΩ at 25°C
3 DC-DC transformer (T01) SWT-47 DC 390V, Secondary DC 12V, 7V
4 Microcomputer TMP87CM40AN
5
Heat exchanger sensor
——— 10kΩ at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-R07190 19mH, AC0.7A
7 Diode (DB01) D3SBA60 4A, 600V
8 Capacitor (C02) KMH400VSSN47M22S 47µF, 400V
9 Fuse (F01) TSCR T6.3A, 250V
10 Varistor (R21, R22) 15G561K 560V
11 Resistor (R01) RF-2TK5R6 5.6Ω, 2W
12 Louver motor MP35EA12
Output (Rated) 2W, 6poles, 4
phase,
DC 12V
4-2. Outdoor Unit (RAS-18UAH-E3)
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH250X3-4LM Winding resistance (Ω) C-R C-S
(at 20°C) 2.29 1.22
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) KFG6-71SB5P-T3 Winding resistance (Ω) Red-Black White-Black
(at 20°C) 64.4 127.4
3
Running capacitor
451205KQ AC 450 V, 2µF
(for fan motor)
4
Running capacitor
371456JCR AC 370 V, 45µF
(for compressor)
5
Solenoid coil
VHV (STF) AC 220 – 240 V
(for 4-way valve)
6 Thermo sensor TE / TD 10 kΩ at 25°C / 50 kΩ at 25°C
7 Magnetic contactor
CLK-26J
220 − 240 V, 50 Hz
8 Transformer TT-05 220 – 240 V
9 Microcontroller TMP47C840N
10 Varistor (R73, R74, R86) 15G471K 470 V
11 Fuse (F01) MT3 T6.3 A, 250 V