FILE NO. SVM-04008
4-6. Outdoor Unit (RAS-24UAH-E3)
No. Parts name Type Specifications
Output (Rated) 2200 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH310X3-4MM Winding resistance (Ω) C-R C-S
(at 20°C) 0.8 2.16
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) KFG6-71SB5P-T1 Winding resistance (Ω) Red-Black White-Black
(at 20°C) 64.4 127.4
3
Running capacitor
451355KQ AC 450 V, 3.5µF
(for fan motor)
4
Running capacitor
DS441606CPB AC 440 V, 60µF
(for compressor)
5
Solenoid coil
VHV (STF) AC 220 – 240 V
(for 4-way valve)
6 Thermo sensor TE / TD 10 kΩ at 25°C / 50 kΩ at 25°C
7 Magnetic contactor CLK-35J 220 − 240 V, 50 Hz
8 Transformer TT-05 220 – 240 V
9 Microcontroller TMP47C840N
10 Varistor (R73, R74, R86) 15G471K 470 V
11 Fuse (F01) MT3 T6.3 A, 250 V
4-7. Outdoor Unit (RAS-24UA-E3, RAS-24UAX3, RAS-24UAX3-T)
No. Parts name Type Specifications
Output (Rated) 2200 W, 2 poles, 1 phase, 220 − 240 V, 50 Hz
1 Compressor 2JS386D5BB02 Winding resistance (Ω ) C-R C-S
(at 20 °C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 − 240 V, 50 Hz
Winding resistance (Ω ) Red-Black White-Black
2 Fan motor (for outdoor)
(at 20 °C) 64.4 127.4
KFG6-71SB5P-T
AC 440 V, 60µF
0.886
1.979
3
Running capacitor
451355KQ AC 450 V, 3.5µF
(for fan motor)
DS441606CPNE
4
5 Magnetic contactor
CLK-35J
220 − 240 V, 50 Hz
Running capacitor
(for compressor)
– 20 –
FILE NO. SVM-04032