– 19 –
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1 Reactor L = 10mH, 16A
2 Outdoor fan motor DC140V, 43W
3 Suction temp. sensor (TS sensor)
10k: (25°C)
4 Discharge temp. sensor (TD sensor)
62k: (20°C)
5 Outside air temp. sensor (TO sensor)
10k: (25°C)
6 Heat exchanger temp. sensor (TE sensor)
10k: (25°C)
7 Terminal block (6P) 20A, AC250V
18SAV-E
22SAV-E
9 COIL FOR P.M.V. DC12V
10 Coil for 4-way valve AC220-240V
CAM-MD12TF-10
STF
Compressor 3-phases 4-poles
1100W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA130A1F-27F
DA150A1F-20F
Parts name Model name Rating
CH-57
ICF-140-43-4R
No.
Fan motor
22SKV-E, 22SKVR-E
(for indoor)
2 Room temp. sensor (TA-sensor)
10k
Ω
at 25°C
3 Heat exchanger temp. sensor (TC-sensor)
10kΩ at 25°C
4 Louver motor Output (Rated) 1W, 16 poles, DC12V
( − )
(
−
)
MP24Z3T
ICF-340-30-2
*
DC-340V,30W
Parts name
1
SpecificationsType
18SKV-E, 18SKVR-E