EasyManua.ls Logo

Toshiba RAS-24UAH-E-1 - Outdoor Unit Electrical Parts

Toshiba RAS-24UAH-E-1
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 19 –
FILE NO. SVM-03010(1)
4-3. Outdoor Unit (RAS-18UAH-E2)
No. Parts name Type Specifications
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
1 Compressor PH250X3-4LM Winding resistance () C-R C-S
(at 20°C) 2.29 1.22
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
2 Fan motor (for outdoor) KFG6-71SB5P-T3 Winding resistance () Red-Black White-Black
(at 20°C) 64.4 127.4
3
Running capacitor
451205KQ AC 450 V, 2µF
(for fan motor)
4
Running capacitor
371456JCR AC 370 V, 45µF
(for compressor)
5
Solenoid coil
VHV (STF) AC 220 – 240 V
(for 4-way valve)
6 Thermo sensor TE / TD 10 k at 25°C / 50 k at 25°C
7 Relay VC20FA 220 – 240 V, 50 Hz, 1P1a
8 Transformer TT-05 220 – 240 V
9 Microcontroller TMP47C840N
10 Varistor (R73, R74, R86) 15G471K 470 V
11 Fuse (F01) MT3 T6.3 A, 250 V
4-4. Indoor Unit (RAS-24UKP-E-1, RAS-24UKPX-1, RAS-24UKP-AR-1, RAS-24UKPX-T-1,
RAS-18UKP-E2, RAS-18UKPX2, RAS-18UKP-AR2, RAS-18UKPX2-T2)
No. Parts name Type Specifications
1 Fan motor (for indoor) ICF-340-30-2 DC 340 V, 30 W
2 Thermo sensor (TA-sensor) ——— 10 k at 25°C
3 DC-DC transformer (T01) SWT-58A DC 390 V, Secondary DC 15 V, 12 V, 7 V
4 Microcontroller TMP87CM40AN
5 Heat exchanger sensor
——— 10 k at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-R07190 19 mH, AC 0.7 A
7 Diode (DB01) D3SBA60 4 A, 600 V
8 Capacitor (C02) KMH450VNSN120M25S 120µF, 450 V
9 Fuse (F01) TSCR T6.3 A, 250 V
10 Relay (for outdoor fan motor,
AJQ1341 Coil DC 12 V, 33 mA, Rated 1 A, AC 250 V
solenoid coil) (RY04)
11 Power supply IC (IC01) MA8920 5 A, 900 V
12 Varistor (R21, R22) 15G561K 560 V
13 Resistor (R01) RF-5TK4R7 4.7 , 5 W
14 Louver motor MP35EA12 Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V

Table of Contents

Related product manuals