AIR CONDITIONER (SPLIT TYPE)
For general public use
Indoor unit
RAS-B05, 07, 10, 13, 16E2KVG-E
RAS-18, 24E2KVG-E
Outdoor unit
RAS-05, 07, 10, 13, 16, 18, 24E2AVG-E
1144180201
OWNER’S MANUAL
R32 or R410A
ENGLISHENGLISH

Other manuals for Toshiba RAS-B07E2KVG-E

Question and Answer IconNeed help?

Do you have a question about the Toshiba RAS-B07E2KVG-E and is the answer not in the manual?

Summary

PRECAUTIONS FOR SAFETY

Warning indications on the air conditioner unit

Identifies and explains warning symbols and their meanings for safe operation.

PREPARATION BEFORE USE

REMOTE CONTROL

SILENT OPERATION

COOLING; HEATING; FAN ONLY OPERATION

DRY OPERATION

TIMER OPERATION

MAINTENANCE

SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY)

TROUBLESHOOTING (CHECK POINT)

The unit does not operate.

Checks to perform when the unit fails to start.

Overview

This document is an owner's manual for a Toshiba Air Conditioner (Split Type) with Inverter technology, designed for general public use. It supports refrigerants R32 or R410A.

Function Description:

The Toshiba Air Conditioner is designed to provide cooling, heating, and dehumidification for indoor spaces. It features an Inverter system for efficient operation. The unit offers various modes including Automatic Operation, Cooling, Heating, Fan Only, Dry Operation, Hi Power Operation, ECO Operation, 8°C Heating Operation, Silent Operation, and Comfort Sleep Operation. It also includes a Self Cleaning Operation to prevent bad smells caused by humidity.

Important Technical Specifications:

  • Refrigerant: R32 or R410A. The appliance is filled with R32.
  • Indoor Unit Models: RAS-B05, 07, 10, 13, 16E2KVG-E; RAS-18, 24E2KVG-E.
  • Outdoor Unit Models: RAS-05, 07, 10, 13, 16, 18, 24E2AVG-E.
  • Operating Temperature Range (Outdoor):
    • Heating: -15°C to 24°C
    • Cooling: -15°C to 46°C
    • Dry: -15°C to 46°C
  • Operating Temperature Range (Room):
    • Heating: Less than 28°C
    • Cooling: 21°C to 32°C
    • Dry: 17°C to 32°C
  • Refrigerant Charge Amount (M): The manual provides a formula to calculate the minimum floor area (Amin m²) required for storage based on the refrigerant charge amount (M in kg) and installation height (h₀ in m). Recommended installation height for these units is 2.5 m.
  • Disconnection Means: The appliance requires a means for disconnection from the supply with a contact separation of at least 3 mm in all poles, incorporated in the fixed wiring.

Usage Features:

  • Remote Control: The unit is operated via an infrared wireless remote control, which can also be used as a wired control. The remote control features buttons for Start/Stop, Mode Select (MODE), Temperature (TEMP), Fan Speed (FAN), Swing Louver (SWING), Set Louver (FIX), 8°C Heating Operation, On Timer (ON), Off Timer (OFF), Setup (SET), Clear (CLR), Memory and Preset (PRESET), Silent Operation (SILENT), High Power (Hi POWER), Eco (ECO), Quiet (QUIET), Comfort Sleep (COMFORT SLEEP), Filter Reset (FILTER), Set Clock (CLOCK), Check (CHECK), and Reset (RESET).
  • Indoor Unit Display: The indoor unit features indicator lights for ECO (White), Wi-Fi access (White) (requires Wireless LAN connecting adapter), Hi POWER (White), Timer (White), and Operation mode (White). Display brightness can be adjusted.
  • Air Flow Direction: Vertical louver direction can be fixed or set to swing automatically. Horizontal direction is adjusted manually.
  • Automatic Operation: Selects cooling, heating, or fan only automatically based on the set temperature (17°C to 30°C).
  • Cooling/Heating/Fan Only Operation: Allows manual selection of Cool, Heat, or Fan only modes with adjustable temperature (17°C to 30°C for Cool/Heat) and fan speed (AUTO, LOW, LOW+, MED, MED+, HIGH). Fan Only mode has no temperature indication.
  • Dry Operation: Provides moderate cooling for dehumidification, with automatic fan speed and adjustable temperature (17°C to 30°C).
  • Hi Power Operation: Automatically controls room temperature and airflow for faster cooling or heating (except in DRY and FAN ONLY mode).
  • ECO Operation: Automatically controls room temperature to save energy (except in DRY and FAN ONLY mode). In cooling, set temperature increases 1°C/hour for 2 hours (max 2°C). In heating, set temperature decreases.
  • 8°C Heating Operation: Maintains an 8°C set temperature for heating. Adjustable from 5°C to 13°C.
  • Silent Operation: Reduces outdoor unit operating noise. Offers two levels: Silent 1 (balances capacity and sound) and Silent 2 (prioritizes sound reduction, reducing max sound by 4 dB(A), potentially compromising capacity).
  • Timer Operation: Allows setting ON, OFF, or Daily timers.
  • Preset Operation: Stores preferred operation settings for future recall (except airflow direction).
  • Temporary Operation: In case of a misplaced or discharged remote control, pressing the RESET button on the indoor unit can start/stop the unit in AUTOMATIC mode, 24°C preset temperature, and automatic fan speed.
  • Comfort Sleep Operation: Automatically controls airflow and turns off after 1, 3, 5, or 9 hours. In cooling, set temperature increases 1°C/hour for 2 hours (max 2°C). In heating, set temperature decreases.
  • Auto Restart Function: The unit automatically restarts in the same operating mode after a power failure. This function is ON by default and can be turned OFF.
  • Manual Defrost Operation: Allows manual defrosting of the outdoor unit's heat exchanger during heating operation by pressing and holding SET for 5 seconds.
  • Remote Control A-B Selection: Allows separation of remote control signals for two indoor units installed nearby, preventing interference.

Maintenance Features:

  • Cleaning:
    • Indoor unit and remote control should be cleaned with a wet cloth. Avoid benzine, thinner, polishing powder, or chemically-treated duster.
    • Air filters should be cleaned every 2 weeks by vacuuming or washing and drying.
  • Self Cleaning Operation (Cool and Dry Operation Only): When activated, the fan continues to run for 30 minutes after the unit is turned off to reduce humidity and prevent bad smells. Can be stopped immediately by pressing the button two more times within 30 seconds.
  • Professional Maintenance: It is recommended that maintenance be performed by a specialist when the unit has been operated for a long time.

Toshiba RAS-B07E2KVG-E Specifications

General IconGeneral
Cooling Capacity2.0 kW
Heating Capacity2.5 kW
RefrigerantR32
Power Supply220-240 V, 50 Hz
TypeSplit System

Related product manuals