1. Press
8°C
button to change to 8°C set temperature heating
operation.
2. Press
to adjust setting temperature from 5°C to 13°C.
Note: 8°C will operate in Heating mode only. If Air conditioner performs in
cooling operation (including automatic cooling) or dry operation it will
change to heating operating.
TEMPORARY OPERATION
8°C OPERATION
12
11
In case of the misplaced or discharged
remote control
Pressing the RESET button, the unit
can start or stop without using the
remote control.
Operation mode is set on AUTOMATIC
operation, preset temperature is 24°C
and fan operation is automatic speed.
TIMER OPERATION
13
Set the timer when the air conditioner is operating.
Setting the ON Timer Setting the OFF Timer
1
Press :
Set the desired ON
timer.
Press : Set the desired
OFF timer.
2
Press : Set the timer. Press : Set the timer.
3
Press : Cancel the timer. Press : Cancel the timer.
Daily timer allows the user to set both the ON & OFF timers and will be
activated on a daily basis.
Setting Daily Timer
1
Press : Set the ON timer.
3
Press .
2
Press : Set the OFF timer.
4
Press button during
the ( or ) mark ashing.
During the daily timer is activating, both arrows ( , ) are indicated.
Note:
Keep the remote control in accessible transmission to the indoor unit;
otherwise, the time lag of up to 15 minutes will occur.
The setting will be saved for the next same operation.
PRESET OPERATION
15
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except air ow direction).
1. Select your preferred operation.
2. Press and hold
for 3 seconds to memorize the setting.
The P mark displays.
3. Press : Operate the preset operation.
AUTO RESTART FUNCTION SETTING
16
This product is designed so that, after a power failure, it can restart
automatically in the same operating mode as before the power failure.
Information
The product is shipped with Auto Restart function in the ON position.
Turn it OFF if this function is not required.
How to turn OFF the Auto Restart Function
Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds but OPERATION lamp does not blink).
How to turn ON the Auto Restart Function
Press and hold the [OPERATION] button on the indoor unit for 3 seconds
(3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).
Note:
In case of ON timer or OFF timer are set, AUTO RESTART OPERATION
does not activate.
To operate at super low fan speed for quiet operation (except in DRY mode)
Press
48,(7
: Start and stop the operation.
Note: Under certain conditions, QUIET operation may not provide adequate
cooling due to low sound features.
For comfortable sleep, automatically control air ow and automatically
turn OFF.
Press
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Note: The cooling operation, the set temperature will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
For heating operation, the set temperature will decrease.
QUIET OPERATION
17
COMFORT SLEEP OPERATION
18
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when
needed.
No benzine, thinner, polishing powder or chemically-treated duster.
Air lters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air lters.
3. Vacuum or wash and then dry them.
4. Reinstall the air lters and close the air inlet grille.
MAINTENANCE
19
DISPLAY LAMP BRIGHTNESS ADJUSTMENT
14
To decrease the display lamp brightness or turn it off.
1. Press and hold
)$1
for 3 seconds until brightness level ( , ,
or ) is shown on remote control LCD then release the button.
2. Press
Rise
or
Decrease
to adjust brightness in 4 levels.
Remote control
LCD
Operation display Brightness
Lamp illuminates full brightness.
100%
Lamp illuminates 50% brightness.
50%
Lamp illuminates 50% brightness and the
operation lamp is turned off.
50%
All lamps are turned off.
All turned off
In the examples of and , the lamp illuminates for 5 seconds before
going off.
SELF CLEANING OPERATION
(COOL AND DRY OPERATION ONLY)
20
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during “Cool” or “Dry” mode,
the fan will continue to run for other 30 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
more 2 times within
30 seconds.
OPERATION /
RESET Button
EN

Other manuals for Toshiba RAS-B07E2KVG-E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba RAS-B07E2KVG-E and is the answer not in the manual?

Toshiba RAS-B07E2KVG-E Specifications

General IconGeneral
Cooling Capacity2.0 kW
Heating Capacity2.5 kW
RefrigerantR32
Power Supply220-240 V, 50 Hz
TypeSplit System

Related product manuals