50
Heating operation/
AUTO (HEAT)
Powerful
SLEEP MODE operation
Dry operation
In the following cases, the angle of the
louver doesnt change even if the
SLEEP signal is received.
Less than 12 minutes from driving
12 to 25 minutes from driving and
Room temp. (Ta) < Set temp. (Tsc) 3.0
In the following cases, the angle of the
louver changes if the SLEEP signal is
received.
12 to 25 minutes from driving and
Room temp. (Ta) Set temp. (Tsc) 3.0
25 minutes or more from driving
Initial setting of
Heating storage position
Louver :
Directs downward (81˚)
Heating storage position
Louver :
Directs downward (81˚)
Heating storage position
Louver : Directs downward (81˚)
Cooling storage position
Louver : Directs downward (23˚)
Only when the operation frequency is
COOL Min–Hz under condition of
Room temp. (Ta) < Set temp. (Tsc) +1.0
PowerfulCooling operation/AUTO (COOL) SLEEP MODE operation
Initial setting of “Cooling storage position”
Louver : Directs downward (23˚)
“Cooling storage position”
Louver : Directs downward (23˚)
Louver : Directs downward (8˚)
Initial setting of “Cooling storage position”
Louver : Directs downward (23˚)
Louver : Directs downward (8˚)
Louver angle
Horizontal
(0˚)
Horizontal
blowing
Inclined
blowing
Blowing
downward
Air direction
Inclined
blowing
Horizontal
blowing
Item
9. Louver control
1) Louver
position
Operation flow and applicable data, etc.
This function controls the air direction of the indoor unit.
Description
Swing operation is performed in width 35° with the stop position as
the center.
If the stop position exceeds either upper or lower limit position, swing
operation is performed in width 35° from the limit which the stop
position exceeded.
3) Swing
2) Louver position in heating operation
Swing
When pressing
[SWING] button during
operation, the louver
starts swinging.
The position is automatically controlled according to the operation mode (COOL/HEAT).
The set louver position is stored in memory by the microcomputer, and the louver returns to the
stored position when the next operation is performed. (Cooling/heating memory position)
The angle of the louver is indicated as the horizontal angle is 0°.
When the louver closes fully, it directs approx. 49° upward.
1) Louver position in cooling operation
2) Air direction adjustment
The louver position can
be arbitrarily set up by
pressing [FIX] button.
3) Louver position in dry operation