– 97 –
Checking procedure
Disconnect the connector and measure the resistance value with tester.
(Normal temp.)
To item of How to judge whether remote control is good or bad of the
Judgment of trouble by symptom.
Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)
Since judgment of DC motor is difficult on the single motor, refer to 10-5-1. (3).
No.
1
2
3
4
Position Resistance value
1 to 4
1 to 6
130 ± 10 Ω
2 to 3
2 to 5
Temperature
Sensor
TA, TC (kΩ)
No.
1
2
3
4
Checking procedure
Measure the resistance value of each winding by using the tester.
Measure the resistance value of winding by using the tester.
For details, refor to Section 10-9.
Check conduction by using the tester.
Disconnect the connector, and measure resistance value with the tester.
(Normal temperature)
Position Resistance value
Red - White 0.2 ± 0.01 Ω
White - Black 0.2 ± 0.01 Ω
Black - Red 0.2 ± 0.01 Ω
Under 20°C
Position Resistance value
Yellow- Pink 5 to 20 kΩ
Sensor
TD (kΩ)
TO, TE, TS (kΩ)
TGa, TGb, TGc, TGd (kΩ)
10-8-3. Indoor Unit (Other Parts)
10-8-4. Outdoor Unit
Part name
Room temp. (TA) sensor
Heat exchanger (TC)
sensor
Remote controller
Louver motor
MP-24GA
Indoor fan motor
Part name
Compressor
(Model : DA220A2F-20L)
Outdoor fan motor
(Model : ICF-140-60-1)
Compressor thermo.
Bimetal type (Model :
US622KXTMQO)
Outdoor temperature
sensor (TO), pipe tem-
perature sensor (TGa,
TGb, TGc, TGd), dis-
charge temperature
sensor (TD), suction
temperature sensor (TS),
evaporator temperature
sensor (TE),
10°C 20°C 25°C 30°C 40°C
20.7 12.6 10.0 7.9 4.5
10°C 20°C 25°C 40°C 50°C
105 64 51 27 18
20.6 12.6 10.0 5.1 3.4
20.0 12.5 10.0 5.3 3.6
Red
White Black
Red
1 Yellow
4 Pink
5 Gray
1
2
3
4
5
White
Yellow
Yellow
Yellow
Yellow