– 20 –
1-1-4. 4-Way Cassette
<Twin type>
Model
Indoor unit1
Outdoor unit
Indoor unit2
RAV-RM
RAV-RM
RAV-GP
561UTP-E
561UTP-E
1101AT-E
801UTP-E
801UTP-E
1401AT-E
Electrical
characteristics
Cooling
Running current (A) 10.19-9.34
2.13
95
4.69
8.57
A++
11.20-10.26
2.34
95
4.79
4.73
A++
20.5
turbo fan
17.5/-/14.5/-/13.0
14
32/-/29/-/28
47/-/44/-/43
15.12-13.86
3.16
95
3.96
8.14
15.36-14.08
3.21
95
4.36
4.72
20.7
turbo fan
20.5/-/16.0/-/13.5
20
35/-/31/-/28
50/-/46/-/43
Sound pressure level Cooling/Heating (dB-A)
Sound power level Cooling/Heating (dB-A)
Connecting pipe
Outdoor unit -
Pipe branch
Gas side (mm)
Liquid side (mm)
Pipe branch-
indoor unit
Gas side (mm)
Liquid side (mm)
Standard air flow highFan unit (m
3
/min)
Motor (W)
Height
difference
Outdoor lower (m)
Outdoor high (m)
Outer dimension
Max total length (m) 75
3
30
30
Propeller fan
116
100+100
15.9
9.5
12.7
6.4
49/50
66/67
75
3
30
30
Propeller fan
116
100+100
15.9
9.5
15.9
9.5
50/51
67/68
Fan
Min length (m)
Sound pressure level (H/M+/M/L+/L) (dB-A)
Sound power level (H/M+/M/L+/L) (dB-A)
Fan
Power consumption (kW)
Power factor (%)
EER
SEER
Energy efficiency class (Lot10)
Heating
Running current (A)
Standard air flow (H/M+/M/L+/L)Fan unit (m
3
/min)
Motor (W)
Power consumption (kW)
Power factor (%)
Maximum current (A)
COP
SCOP
Energy efficiency class (Lot10)
Cooling capacity (kW) 10.0
11.2
12.5
14.0
Heating capacity (kW)
Power supply 1phase 220-240V/50Hz
Indoor unit
Outdoor unit