– 53 –
GP80
Less than
38 rps
38rps or more
and less than 52rps
52rps
or more
Maximum
W7
W9
WD
WE
WF
WF
-2 taps/20sec
stop timer count
(Until W1)
-2 taps/20sec
(Until W1)
W9
WD
WE
WE
WF
WF
W8
WB
WD
WE
WF
WF
15
18
21
24
-2 taps/20sec
(Until W1)
Revolution number HOLD
+1tap /20sec
10˚C ≤ TO
5˚C ≤ TO < 10˚C
-3˚C ≤ TO < 5˚C
-10˚C ≤ TO < -3˚C
TO < -10˚C
To trouble
Less than
38 rps
GP110
GP140
38rps or more
and less than 52rps
52rps
or more
Maximum
WA
WC
WC
WE
WE
WE
-2 taps/20sec
stop timer count
(Until W1)
-2 taps/20sec
(Until W1)
WC
WC
WE
WE
WE
WE
WB
WC
WC
WE
WE
WE
15
18
21
24
-2 taps/20sec
(Until W1)
Revolution number HOLD
+1tap /20sec
10˚C ≤ TO
5˚C ≤ TO < 10˚C
-3˚C ≤ TO < 5 ˚C
-10˚C ≤ TO < -3˚C
TO < -10˚C
To trouble
3-2. Heating fan control
1) Heating operations of the outdoor fan are controlled by a TE sensor, TO sensor and the compressor
revolution number.
(Control from a minimum W1 to a maximum is performed according to the table below).
2) Operation is fixed for 3 minutes after start up by a maximum fan tap corresponding to the zones in the
table below. Thereafter fan control is performed using the temperature from the TE sensor.
3) When TE ≥ 24°C continues for 5 minutes, the compressor is stopped. The compressor is placed in the
same state as a normal thermostat OFF without a check code display.
The compressor is restarted after approximately 2 minutes 30 seconds and such interrupted operation
does not constitute a trouble.
When the operation in 3) above is frequently performed, the filter of the intake section of the indoor unit
may require cleaning.
Therefore restart operation after cleaning the filter.