SERVICE MANUAL
AIR-CONDITIONER
(SPLIT TYPE)
FILE NO. SVM-13050-6
INDOOR UNIT
<Ceiling type>
RAV-SM567CTP-E (TR)
RAV-SM807CTP-E (TR)
RAV-SM1107CTP-E (TR)
RAV-SM1407CTP-E (TR)
RAV-SM1607CTP-E (TR)
SVM-13050.indb 1SVM-13050.indb 1 6/27/13 10:35 AM6/27/13 10:35 AM
Revised on Mar. 2014

Other manuals for Toshiba RAV-SM567CTP-E

Questions and Answers

  • A
    ashleyreyesSep 15, 2025
    What does outdoor unit temp. sensor (TE/TS) error mean on Toshiba Air Conditioner?
    • P
      Peter DavidsonSep 16, 2025
      If your Toshiba Air Conditioner displays an outdoor unit temp. sensor (TE/TS) error, it means an open-circuit or short-circuit of the heat exchanger temp. sensor was detected. This is related to the Outdoor temp. sensors (TE/TS) or the outdoor P.C. board, and the entire system will stop.
  • R
    Robin KlineAug 25, 2025
    What causes an outdoor unit fan error in a Toshiba Air Conditioner?
    • D
      David RodriguezAug 25, 2025
      An error (overcurrent, locking, etc.) was detected in the outdoor unit fan drive circuit. This could be due to the outdoor unit fan motor or the outdoor unit P.C. board.
  • M
    Mark SimmonsAug 25, 2025
    What does it mean when the outdoor unit inverter Idc is activated in my Toshiba RAV-SM567CTP-E?
    • J
      Jason AnthonyAug 26, 2025
      A short-circuit protection for compressor drive circuit devices (G-Tr/IGBT) was activated and this could be related to the IGBT, outdoor unit P.C. board, inverter wiring, or the compressor.
  • J
    Jillian SmithAug 27, 2025
    What does it mean when my Toshiba Air Conditioner displays an outdoor unit discharge temp. sensor (TD) error?
    • C
      Charles BuchananAug 27, 2025
      The discharge temp. sensor has an open-circuit or short-circuit. Check the outdoor temp. sensor (TD) and the outdoor P.C. board.
  • G
    gonzalezmarkSep 16, 2025
    What does outdoor unit outside air temp. sensor error mean on Toshiba RAV-SM567CTP-E?
    • R
      Robin BarkerSep 16, 2025
      If your Toshiba Air Conditioner displays an outdoor unit outside air temp. sensor error, it means an open-circuit or short-circuit of the outdoor air temp. sensor was detected. This is related to the Outdoor temp. sensor (TO) or the outdoor P.C. board, and operation will continue.
  • A
    Amanda TaylorSep 23, 2025
    What does indoor unit-remote controller regular communication error mean on Toshiba Air Conditioner?
    • C
      Crystal SanchezSep 23, 2025
      No data is received from the remote controller or network adapter.
  • R
    Richard GrahamSep 8, 2025
    What causes an outdoor unit fan error in my Toshiba RAV-SM567CTP-E?
    • A
      April KelleySep 8, 2025
      If your Toshiba Air Conditioner displays an outdoor unit fan error, it means an error (overcurrent, locking, etc.) was detected in the outdoor unit fan drive circuit. This could be due to the outdoor unit fan motor or the outdoor unit P.C. board, and it will cause the entire system to stop.
  • D
    Destiny McdonaldSep 9, 2025
    What does the fan error of the indoor unit mean on my Toshiba RAV-SM567CTP-E?
    • R
      Rebecca ClaytonSep 9, 2025
      If your Toshiba Air Conditioner displays the fan error of the indoor unit, it indicates abnormal operation (over current or lock, etc.) is detected. This is related to the indoor fan motor or indoor P.C. board and the system will entirely stop.
  • G
    gregory60Sep 2, 2025
    What does it mean if there are duplicated header remote controllers in my Toshiba RAV-SM567CTP-E setup?
    • D
      Deborah MartinezSep 3, 2025
      Two remote controllers are set as header in the double-remote controller control. This is a remote controller address setting error.
  • R
    Rebecca WilliamsAug 31, 2025
    What causes a header unit follower unit regular communication error in a Toshiba Air Conditioner?
    • L
      Lauren AndersonSep 1, 2025
      Regular communication is not possible between header and follower indoor units or between twin header (main) and follower (sub) units. Check the indoor P.C. board.

Toshiba RAV-SM567CTP-E Specifications

General IconGeneral
SEER6.1
RefrigerantR32
TypeSplit System
Energy Efficiency Ratio (EER)3.2
Coefficient of Performance (COP)3.6
Power Supply220-240V, 50Hz