VRF DX COIL INTERFACE
MODEL NAME
Dx-coil controller
TCB-IFDMX01UP-E
(Terminal block without relay)
TCB-IFDMR01UP-E
(Terminal block with relay)
Dx-valve kit
RBM-A101UPVA-E
RBM-A201UPVA-E
Design Guideline
DG003-03

Other manuals for Toshiba RBM-A101UPVA-E

Questions and Answers

  • D
    David MataAug 9, 2025
    What to do if my Toshiba RBM-A101UPVA-E Air Conditioner safety contact has trouble?
    • S
      Scott JohnsonAug 9, 2025
      If you are experiencing safety contact issues with your Toshiba Air Conditioner, inspect the contact at terminals DI1 / DI1. If the contact is open, check code P10 is generated. If the contact is not in use, ensure a bridge connection is installed on the terminals DI1 / DI1.
  • K
    kaitlin57Aug 15, 2025
    What to do if my Toshiba Air Conditioner shows an external trouble?
    • Y
      yrobinsonAug 15, 2025
      If your Toshiba Air Conditioner indicates an external issue, check the fan's operation monitoring at terminals DI2 / DI2. If this contact is closed, the check code L30 will be generated.
  • G
    Gregory SharpAug 21, 2025
    What to do if my Toshiba RBM-A101UPVA-E shows TA sensor trouble?
    • C
      carolyn24Aug 21, 2025
      If your Toshiba Air Conditioner displays a TA sensor issue, check the connection of the TA sensor connector and wiring. Also, check the resistance characteristics of the TA sensor and inspect the indoor P.C. board for any problems.
  • A
    adamhollowayAug 27, 2025
    What causes an incompatible group combination of indoor units in a Toshiba Air Conditioner?
    • J
      Jacqueline ElliottAug 27, 2025
      An incompatible group combination of indoor units in your Toshiba Air Conditioner may be caused by incorrect model matching or a problem with the indoor P.C. board. Check the indoor units' model names and inspect the indoor P.C. board for any issues.
  • E
    Eric DavisSep 3, 2025
    What causes a duplicated master remote controller issue in Toshiba RBM-A101UPVA-E?
    • V
      vhudsonSep 3, 2025
      A duplicated master remote controller issue in your Toshiba Air Conditioner occurs when two remote controllers are set as the master. Check the remote controller inter-unit tie cable (A/B).

Summary

Application and System Overview

Application Types and Settings

Details on application types (TA, DDC, TF) and their configuration via SW501.

System Compatibility

Explains system compatibility with various Toshiba outdoor units and control types.

DX COIL Technical Guidelines

Operating Conditions and Pipe Sizing

Specifies operating temperatures and guidelines for selecting pipe sizes based on capacity.

DX COIL Design Guidelines

Comprehensive guide for AHU/DX COIL selection, including procedures, correction charts, and specific design patterns.

Product Configuration and Specifications

Product Configuration

Details product combinations of Dx-coil controllers and Dx-valve kits for various HP ranges.

Major Specifications

Lists key specifications for Dx-coil controllers and Dx-valve kits, including dimensions and weights.

Wiring, Controls, and I;O

Analog and Digital I;O

Details analog and digital input/output functions, their specifications, and wiring requirements.

Modbus Communication Setup

Guides on setting up Modbus communication, including wiring methods and switch configurations.

Installation, Manufacturing, and Troubleshooting

DX COIL Manufacturing and Installation

Outlines manufacturing standards and installation procedures for DX COIL, controllers, valve kits, and sensors.

Control Outline and Protection Functions

Explains control logic, DDC programming cautions, and summarizes essential protection functions of the system.

Check Codes and Troubleshooting

Lists common check codes and their potential causes, aiding in troubleshooting system errors.

System Integration and Cautions

Cable Specifications

Specifies cable types, sizes, and lengths for communication lines and remote controller wiring.

Compatibility and Dimensions

Provides physical dimensions and compatibility information for controllers, valve kits, and network interfaces.

Related Cautions and Warranty

Provides important cautions regarding installation, operation, service, and warranty information.

Toshiba RBM-A101UPVA-E Specifications

General IconGeneral
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
RefrigerantR32
Power Supply220-240V, 50Hz
TypeSplit System