What does error E16 mean on my Toshiba Heat Pump?
- JJade EstradaAug 13, 2025
If your Toshiba Heat Pump displays error code E16, this indicates either a capacity overload (00) or an issue with the number of connected units (01~).
What does error E16 mean on my Toshiba Heat Pump?
If your Toshiba Heat Pump displays error code E16, this indicates either a capacity overload (00) or an issue with the number of connected units (01~).
What does error E20 mean on a Toshiba Heat Pump?
Error code E20 on your Toshiba Heat Pump indicates that another line is connected during automatic addressing. This could mean either another outdoor line (01) or another indoor line (02) is connected.
What does error E19 mean on my Toshiba Heat Pump?
Error code E19 on your Toshiba Heat Pump indicates an issue with the header outdoor units. Specifically, it could mean that there is no header unit (00) or that there are two or more header units (02).
What does it mean if my Toshiba Heat Pump shows error code E06?
If you see error code E06 on your Toshiba Heat Pump, it indicates a decrease in the number of indoor units that are normally received.
What does error code E23 mean for a Toshiba Heat Pump?
If your Toshiba Heat Pump is showing error code E23, it indicates a sending error between the outdoor units during communication.
What does it mean when my Toshiba Heat Pump displays error code E25?
If your Toshiba Heat Pump displays error code E25, it means there is a duplicated follower outdoor address setup.
What does error code E26 signify on a Toshiba Heat Pump?
If your Toshiba Heat Pump shows error code E26, it indicates a decrease in the number of outdoor units that are normally received.
What does error E28 mean on my Toshiba Heat Pump?
If your Toshiba Heat Pump displays error code E28, it indicates an error with the follower outdoor unit. The error code will show the detected outdoor unit number.
Brand | Toshiba |
---|---|
Model | Super MMY-MAP1001HT8 |
Category | Air Conditioner |
Language | English |
Specifications for the cooling-only outdoor unit model.
Specifications for the 50Hz heat pump outdoor unit model.
Specifications for the 60Hz heat pump outdoor unit model.
Explains the meaning of WARNING and CAUTION symbols used in the manual.
Details on power supply requirements and specifications for outdoor units.
Diagrams and specifications for electrical wiring configurations.
Explains the wiring for control signals between units.
Overall wiring diagram for the system including indoor and outdoor units.
Instructions for connecting power and control cables to the outdoor unit.
Procedures for automatic indoor unit address configuration.
Step-by-step guide for automatic address setup.
Step-by-step guide for system address setup on the PC board.
How to set addresses using a wired remote controller.
Procedures to reset unit addresses to factory default settings.
Pre-checks and warnings before performing a test operation.
How to conduct a test operation using the wired remote controller.
Performing test operations via switches on the outdoor unit's PC board.
How to diagnose outdoor unit issues using the 7-segment display.
Detailed list of outdoor unit error codes and their meanings.
Guidelines for refrigerant concentration limits in installed rooms.