3. Remove the power supply unit. (Refer to section 4.9.)
4. If the power supply connector (PJ6 and PJ10) on the system board is
connected properly, go to PROCEDURE 3.
If it is not connected properly, reconnect it.
<fig id=MMS\5200\52002_7.TIF>Page 2-7</fig>
PROCEDURE 3
Output Voltage Check
1. Plug the AC power cord to the power supply unit, then turn on the
power.
2. Use a multimeter to confirm that the output voltages of the three
power supply connectors match to the values in table 2-1.
3. If the voltages are within the range of values given in table 2-1,
the power supply unit is normal, but the system board is probably
defective. Go to the system board isolation procedures in section
2.4.
4. If the voltages are still not within the range of values given in
table 2-1, go to PROCEDURE 4.
Table 2-1 Power supply unit output voltages
ÚÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³ ³Pin number ³ Voltage ( Vdc) ³
³Connector ÃÄÄÄÄÄÂÄÄÄÄÄÅÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄ´
³ ³+lead³-lead³Normal³ Min ³ Max ³
ÃÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ´
³ ³ 1 ³2,4,5³ 24 ³ 19.2 ³ 28.8 ³
³ For ÃÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ´
³ system ³ 3 ³2,4,5³ 12 ³ 11.4 ³ 12.6 ³
³ board ÃÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ´
³ ³6,7 ³2,4,5³ 5 ³ 4.75 ³ 5.25 ³
ÃÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ´
³ For ³ 1 ³ 3 ³ -12 ³ -13.2 ³ -10.8 ³
³ system ÃÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ´
³ board ³ 2 ³ 3 ³ -5 ³ -5.25 ³ -4.75 ³
ÃÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ´
³ For ³ ³ ³ ³ ³ ³
³ cooling ³ 1 ³ 2 ³ 12 ³ 11.4 ³ 12.6 ³
³ fan ³ ³ ³ ³ ³ ³
ÀÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÙ
<fig id=MMS\5200\52002_8.TIF>Page 2-8</fig>
PROCEDURE 4
Power Supply Unit Replacement
1. Turn off the power, then unplug the AC power cord.
2. Replace the power supply unit. (Refer to section 4.9.)
3. If normal operation is restored after replacing the power supply
unit, the original power supply unit was probably defective.