EasyManua.ls Logo

Toshiba TDP-T8 - Inspection Procedure

Toshiba TDP-T8
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S8 T8 T9
4-5
Note: Do Reset in OSD menu before function test.
- Frequency and Tracking
Test Signal : 1024x768@60Hz (T8/T9); 800x600@60Hz (S8)
Test Pattern : Line Moire Pattern
* Check and see if image sharpness and focus are well performed.
* If not, readjust by following steps.
(1) Select Frequency function to adjust the total pixel number of pixel
clock in one line period.
(2) Then select Phase function and use right or left arrow key to adjust the
value to minimize video flicker.
- Boundary
Test Signal : 1024x768@60Hz (T8/T9); 800x600@60Hz (S8)
Test Pattern : Boundary Frame
* Adjust Resync or adjust Frequency/H. Position/V. Position to the inner of
the screen.
- Focus
Test Signal : 1024x768@60Hz (T8/T9); 800x600@60Hz (S8)
Test Pattern : Text Pattern
* Adjust the center clearly, meanwhile, one slightly vague corner in the image is
allowed
Calibration in Factory Mode
(See Page 4-7 or Appendix for hotkeys)
After Main Board is changed or firmware is upgrade, the calibration is needed to
ensure good color performance.
- Video Calibration
Test Signal : HDTV Signal (720p) (Plug in HDTV signal cable into VGA port)
Test Pattern : Calibration Pattern (Figure 12)
Get into Factory Mode to execute video calibration.
- ADC Calibration (PC Calibration)
Test Signal : 1024x768@60Hz (T8/T9); 800x600@60Hz (S8)
Test Pattern : Calibration Pattern (Figure 13)
* Enter Factory Mode to execute PC Calibration.
4-4 Inspection Procedure