E6581611
G-5
7
List of logic input terminal function settings
Parameter
programmed value
Function
Parameter
programmed value
Function
Positive
logic
Negative
logic
Positive
logic
Negative
logic
No function
  Integrating wattmeter (kWh) display
clear
Forward run command   Trace back trigger signal
Reverse run command
  Light-load high-speed operation
prohibitive signal
Standby   Holding of RY-RC terminal output
Reset command   Holding of OUT-NO terminal output
  Preset-speed command 1   Frequency UP *2
  Preset-speed command 2   Frequency DOWN *2
  Preset-speed command 3   Clear frequency UP/DOWN *2
  Preset-speed command 4   Coast stop command
  Jog run mode   Forward/reverse selection
  Emergency stop by external signal   Run/Stop command
  DC braking command
  Frequency reference command forced
switching
  2nd acceleration/deceleration   Frequency setting mode terminal block
  3rd acceleration/deceleration   Command mode terminal block
  2nd V/F control mode switching   Parameter editing permission
  2nd stall prevention level   Fast stop command 1
  PID control prohibition   Fast stop command 2
  External thermal error input   Traverse permission signal
  Forced local from communication   Low voltage operation
  Operation hold (hold of 3-wire operation)   Forward deceleration
  PID integral/differential clear   Forward stop
  PID characteristics switching   Reverse deceleration
  Forced run operation   Reverse stop
  Fire speed operation  to  Factory specific coefficient *1
  Acceleration/deceleration suspend signal   No.2 motor switching
  Power failure synchronized signal   Parameter editing prohibition
  Factory specific coefficient *1   Parameter reading prohibition
  Factory specific coefficient *1 
*1: Factory specific coefficients are manufacturer setting menus. Do not change the value of these parameters.
*2: Active when  (frequency setting mode selection) = (UP/DOWN from external logic input) is set.
The frequency setup range is from  to  (maximum frequency). The acceleration/deceleration time
relative to the set frequency is / while the acceleration/deceleration speed is not switched.
Refer to section 11.6 for details about the input terminal function.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VFS15-4075PL-W and is the answer not in the manual?

Toshiba TOSVERT VFS15-4075PL-W Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VFS15-4075PL-W
CategoryInverter
LanguageEnglish

Related product manuals